Regulatory Compliance
VitalScreen CSR
This display has been tested and found to comply with IEC/EN 60601-1
and IEC/EN 60601-1-2 standards, and is certified to meet medical
standard C22.2 No. 601.1-M1990 (C US Mark).
The medical display, in addition to meeting medical requirements,
has been tested and found to comply with the limits for Federal
Communications Commission (FCC) Class B computing devices in
a typically configured system since many medical offices are located in
residential areas. It is the system integrator’s responsibility to test and
ensure that the entire system complies with applicable electromagnetic
compatibility (EMC) laws.
Planar Systems, Inc. has made great efforts to support the medical
device industry, in particular, medical device manufacturers and medical
device system integrators. We offer state-of-the-art color displays that are
compliant with worldwide accepted medical device safety standards, and
for the European market, CE-marked displays based on compliance with
counsel directive 93/42/EEC—commonly referred to as the Medical Device
Directive (MDD). The following summarizes our qualification of these
displays as it relates to compliance with the MDD.
The European Medical Device Directive requires that the intended use
of the device be defined. The intended use of these displays is “to display
alphanumeric, graphic, and image data as inputted from any type of
medical device.” These displays do not provide a measurement function
in any way, and it is the device and systems manufacturer’s responsibility
to verify its function in the integrated device or system.
The display was classified as required by the MDD according to Annex IX
of the directive and the medical device (MEDDEV) guidance available
at the time of classification. Because the display uses electrical energy
and has no direct patient connections andby itselfno medical utility,
the display is classified according to Rule 12 as an MDD Class I device-
component or accessory. The MDD states that manufacturers of Class I
medical devices or accessories shall satisfy the requirements in regard
to design and manufacturing controls, that is, the applicable assessment
route to be used for CE-marking under the MDD, and it shall carry
the CE mark according to Annex XII of the directive, with no notified
body annotation.
The applicable safety standards for an MDD Class I display are
IEC/EN 60601-1:1900 along with Amendments 1 and 2. To help the
medical device designer evaluate the suitability of these displays,
Planar has also conducted EMC testing to IEC 60601-1-2 as it can
be applied. The display with its power supply alone does not represent
a functional medical device. Hence, Planar configured a minimal
operating system to exercise the display. The resulting data are
made available to interested parties.
The data are informative data, not certification data. Certification
data must be obtained by the device or system integrator according
to Article 12 of the MDD titled “Particular procedure for systems and
procedure packs.” Paragraph 2 clearly outlines the device or system
integrator’s responsibility in this matter.
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
iv
In summary, Planar Systems, Inc. is CE-marking these displays
under the Medical Device Directive, which establishes compliance to
the basic medical safety standards. However, EMC compliance can
only be accomplished in the configured medical device or system and
is the responsibility of the device or system manufacturer. Planar has
the necessary documentation such as IEC 60601-1 notified body and
other third-party test reports and certifications, a risk/hazard analysis,
an essential requirements checklist, and the Planar International
Electrotechnical Commission (IEC) declaration of conformity.
Planar Systems, Inc., located in Beaverton, Oregon, USA, is the
manufacturer of these displays in the meaning of the directive.
As required by the MDD in Article 14, Planar Systems, Inc., not
residing in the European Economic Area (EEA), has a European
representative, Planar Systems, Inc.Espoo, Finland.
In the opinion of Planar Systems, Inc. registration required to put this
device into commerce is the responsibility of the medical device/system
manufacturer, and Planar supports this requirement by providing a
European Commission (EC) declaration of conformity. If Planar supplies
a display to an end user, rather than a device manufacturer, it is the end
user’s responsibility to ensure continued compliance with the MDD of
the system in which the display is integrated.
For vigilance reporting as required under Article 10 of the MDD,
Planar Systems, Inc. will provide any information requested by
competent authority to support any reported incident investigation
by such an authority.
European Union Declaration of Conformity for Medical Applications
A Declaration of Conformity has been filed for this product. For
additional copies of the Declaration of Conformity document, contact
Planar Systems, Inc. and request document number 001-0014-05
“Declaration of Conformity.”
VitalScreen CR
Manufacturer Declaration
This certifies that this product is in compliance with the EU Directive
89/336/EEC, using the EMC standards EN55022 (class B), EN50081-1
and EN50082-1. This product meets or exceeds EN60950, UL1950, and
CSA 22.2 No. 950 safety requirements. This product has been tested and
verified to meet CISPR 22 Class B requirements.
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
v
FCC Compliance Statement
This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment
off and on, you are encouraged to try to correct the interference by one or
more of the following measures:
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet different from that to which
the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
To comply with the limits for an FCC Class B computing device,
always use the shielded signal cord and shielded power cord supplied
with this unit.
The Federal Communications Commission warns that changes or
modifications of the unit not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
vii
Contents
About This Manual .............................................................. ix
Product Information............................................................. x
1 The VitalScreen 17.4" Display........................................... 1
VitalScreen CSR ...................................................................... 2
VitalScreen CR......................................................................... 2
Distinguishing the Displays ................................................... 2
Selecting a Workspace............................................................. 3
Unpacking the Display............................................................ 3
Identifying the Components ................................................... 4
2 Installing the Display........................................................... 7
Safety Precautions ................................................................... 7
Connecting the AC Power to the Display .............................. 7
Connecting the Display to the System ................................... 8
Connecting a Video Device...................................................... 9
Connecting the Optional Touch Screen ................................. 9
Mounting the Display.............................................................. 9
Power Management System ..................................................10
Landscape-to-Portrait Mechanical Conversion ....................10
3 The Display Controls..........................................................11
Using the Onscreen Display ..................................................11
Onscreen Display Main Menu ...............................................11
S-Video and Composite Video Settings .................................15
Onscreen Display Lockout .....................................................16
Supported CVBS and S-Video Modes....................................16
Appendix A: Technical Information................................19
Appendix B: Troubleshooting..........................................20
Index .......................................................................................21
Description of Warranty.....................................................23
Ordering Information..........................................................25
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
ix
About This Manual
Congratulations on your purchase of the VitalScreen display!
This operations manual will help you set up, use, and maintain
the VS17.4SXAD or CM17.4SXAD model properly. Retain this
manual for future reference.
Read this section carefully to learn how to handle the display safely
and clean it correctly. It explains the symbols used on the products
and the conventions used in this manual.
Chapter 1 provides an overview of the VitalScreen display. It lists
the contents of the display package and identifies the components of
the display.
Chapter 2 explains how to install the display correctly and use
optional components.
Chapter 3 explains the menus and function controls built into
the display.
Appendix A contains technical information.
Appendix B focuses on troubleshooting.
Warranty description and ordering information are provided at
the back of this manual.
Conventions
The VitalScreen display documentation uses these conventions.
This convention…
Indicates…
A warning that can prevent injury to you,
such as electric shock.
A note of important information regarding
a particular topic or procedure.
A caution that can prevent potential damage
to hardware or software.
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
x | Product Information
Product Information
Safety Instructions
Store the display in its original shipping carton when it is not in
operation for extended periods of time. Also use the original packing
materials and carton when shipping the display.
•
•
•
•
Do not place the display near a window. Exposing the display to rain,
water, moisture, or constant direct sunlight can damage it.
Do not place anything on top of the display-to-computer signal cord.
Make sure the cord is placed where it will not be stepped on.
Do not apply excessive pressure to the screen. Excessive pressure
may cause permanent damage to the display.
Do not operate the touch screen with sharp objects, such as a scalpel.
Sharp objects can scratch or damage the touch screen. A damaged
touch screen may pose a safety hazard.
•
Refer all servicing to qualified personnel to maintain your
warranty. The display and power supply units contain no
user-serviceable parts.
•
•
Do not cover or obstruct the venting holes on the back of
the display.
Store the display in an environment with a temperature
range from −20 to 65 degrees Celsius (from −4 to 149 degrees
Fahrenheit). Storing your display outside that temperature
range could result in permanent damage.
•
Replace any cord or cable that is frayed or damaged with
another of the same type and rating as supplied by Planar.
(See “Ordering Information” at the end of this manual for part
numbers.) The safety and regulatory listings and certifications
are based on the cable supplied by Planar.
•
•
Do not expose the display to liquid or drop it. If the case has been
damaged, the unit may pose a shock or fire hazard. Unplug the unit
immediately and call customer service for assistance.
Use only the power adapter that has been tested and approved
for use with this display product. (See “Ordering Information” for
part numbers.)
The power adapter must be plugged into a grounded power outlet.
•
•
Use a cloth dampened with liquid cleaner to clean the power adapter.
Wipe the outside of the enclosure and cable only. Do not immerse the
adapter in liquid, or a safety hazard could arise during use.
Do not use the power adapter near inflammable anesthetics.
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
Product Information | xi
Cleaning Instructions
The VitalScreen display will continue to operate while being cleaned in
a fashion normal for a hospital environment. This means cleaning the
display with a damp, mild soapy cloth.
The VitalScreen withstands nonabrasive cloths and cleaning solutions
used in hospital for like equipment. This cleaning typically includes warm
water and mild detergent for all surfaces or 70 percent isopropyl alcohol
for the touchscreen surface.
Possible cleaning solutions
•
•
•
•
•
•
•
•
•
70 percent isopropyl alcohol
1.6 percent aqueous ammonia
Cidex (2.4 percent glutaraldehyde solution)
Sodium hypochlorite (bleach) 10 percent
“Green soap” United States Pharmacopoeia (USP)
0.5 percent Chlorhexidine in 70 percent isopropyl alcohol
Ovation
Formula 409
Fantastic
•
WexCide
To clean the screen
Stand away from the display and spray the cleaning solution onto
a clean nonabrasive cloth. Without applying excessive pressure, clean
the screen with the slightly dampened cloth. Dry the screen with
a clean nonabrasive cloth to remove any residue.
Do not spray liquid cleaners directly onto the screen.
Disposal Information
The VitalScreen display contains cold cathode fluorescent lamps, which
contain a maximum of 20 milligrams of mercury (5 milligrams per lamp).
Follow local ordinances or regulations for its disposal.
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
xii | Product Information
Symbol Explanations
This table explains the symbols appearing on the display or power
supply adapter.
This symbol…
Indicates…
Proof of conformity to applicable European Economic
Community Council directives and two harmonized
standards published in the official journal of the
European Communities.
The product has been tested to specific requirements of
medical or ITE device standards. If this mark appears with
the indicators “C” and “US,” the product is certified for the
Canadian and U.S. markets, meeting the applicable
Canadian and U.S. standards.
The product has been tested to comply with
FCC Class B standards.
More information available in accompanying documents.
Protective earth ground.
The product has been tested to comply with Underwriters’
Laboratories standards.
Indoor use only.
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
The VitalScreen 17.4" Display
The architecture of the VitalScreen CSR and VitalScreen CR displays
incorporate an active matrix liquid-crystal display (AMLCD) panel that
produces a bright, high-contrast image with low radiation emission.
This technology greatly reduces the radiation-related health concerns
associated with cathode-ray tube (CRT) monitors.
Each VitalScreen is a high-resolution color display designed to be
versatile and easy to use. The display accepts either analog or digital
video (DVI) input and displays most video standards from 640 x 480
(VGA standard) to 1280 x 1024 (SXGA standard). The controls located
on the front panel allow you to easily adjust the display parameters
using onscreen display (OSD) menus.
The digital video input is a single-link, transition minimized differential
signaling (TMDS) digital visual interface (DVI), and is in compliance
with the Digital Display Working Group (DDWG) DVI standard. This
interface produces the sharpest display image possible with little need
for adjustment. The setup is Plug and Play.
Each display has a built-in mounting platform that conforms to the
Video Electronics Standards Association (VESA) mounting standard.1
This configuration allows the display to be mounted in a variety of
ways, such as on a wall bracket or articulated swing arm. An alternate
configuration with a desk stand is also available for easy use on flat
work surfaces.
Both displays have features making them ideal for hospital applications.
The housing is an acrylic cover that protects the display from bumps,
falls, collisions, and even everyday cleaning. In addition, Planar offers
configuration management to ensure that you receive a consistent and
predictable product.
The Planar 17.4" display series, for the first time, consists of these two
distinct versions: VitalScreen CSR and VitalScreen CR. Both displays
have been designed for hospital use, but they have several differences.
1 The VESA Flat Panel Monitor Physical Mounting Interface (FPMPMI)
Standard defines physical mounting interfaces for flat-panel displays,
corresponding standards (75 and 100 millimeters) for flat-panel display
mounting devices, and associated cable, cable connectors, and power supply
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
2 | The VitalScreen 17.4" Display
VitalScreen CSR
This display has been designed, tested, and certified for use within
the patient vicinity. It has lower electric discharge, thus reducing
the likelihood of electric shock. The display is certified to UL-2601,
IEC 60601-1, and other representatives of the most stringent electric
discharge certifications available. In addition, the interface buttons on
the front panel are sealed by a plastic membrane, allowing simpler and
safer cleaning. The display also meets the liquid/particle ingress
certifications, IPX-1.
VitalScreen CR
This display has been designed for hospital use outside the patient
vicinity. It is not certified UL-2601 or IEC 60601-1. In addition, the
interface buttons are not sealed on the front panel, and the display
does not meet IPX-1 standards.
The VitalScreen CR display has been tested and found to comply with
the limits for a Class B digital device pursuant to Part 15 of FCC rules.
The interface buttons on the VitalScreen CR display are not sealed
and can be harmed if exposed to liquids. Use caution when cleaning
near the front panel.
Distinguishing the Displays
Many of the features and benefits that differentiate the VitalScreen CSR
and VitalScreen CR displays are not visually apparent. The simplest way
to identify your Planar display is to check the interface buttons on the
front panel.
Note these differences for the interface buttons:
•
Interface buttons on the front panel of the VitalScreen CSR display
(left) are sealed by a plastic membrane.
•
Interface buttons on the front panel of the VitalScreen CR display
(right) are not sealed.
The display on the cover of this manual is a VitalScreen CSR. A plastic
membrane seals the interface buttons.
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
The VitalScreen 17.4" Display | 3
Selecting a Workspace
Before unpacking the display, prepare a suitable workspace. You need
a stable and level surface near a grounded wall outlet in an area that
is relatively free of glare from sunlight or other sources of bright light.
The display is cooled by natural convection. For best performance,
do not block the cooling vents.
Unpacking the Display
While unpacking the display, inspect it and other package contents for
shipping damage that could cause a fire or shock hazard. Immediately
report any shipping damage to the carrier or transport company, and
contact customer service for assistance. Keep all packing material in
case you need to ship, store, or return the display.
After you unpack the display, make sure you have these items:
•
•
•
LCD screen
AC power supply with 1.5-meter (5-foot) cable
Power cord for the display, which connects from the AC main supply
to the AC adapter
•
•
•
3-meter (9-foot) S-Video/Composite Video cable (if you purchased the
VitalScreen CSR with S-Video and Composite Video support)
3-meter (9-foot) audio cable (if you purchased the VitalScreen CSR
with S-Video and Composite Video support)
75 and 100 millimeter VESA plates (if you purchased
the VitalScreen CSR without a desk stand)
•
2-meter (6-foot) RS-232 serial cable (if you purchased
the VitalScreen CSR with touchscreen interface)
•
•
•
2-meter (6-foot) analog video cable (VGA-VGA) with audio
2-meter (6-foot) digital video cable (DVI-DVI) with audio
Documentation package including CD, operations manual in English,
and EU Declaration of Conformity
If you have questions about what comes with your display, compare the
part number for the display with the ordering information on page 25.
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
4 | The VitalScreen 17.4" Display
Identifying the Components
The VitalScreen CSR and VitalScreen CR displays provide easy access to
all controls and peripheral ports. The following illustrations of the screen
and the front and back panels identify the display controls and ports.
17.4" LCD screen
LCD screen
A 17.4-inch diagonal AMLCD. The screen supports
most display standards from 640 x 480 VGA to
1280 x 1024 SXGA.
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
The VitalScreen 17.4" Display | 5
Front panel
Power switch /
Dual function button to control display
Onscreen display
power and access the OSD menu. Press
this button for 2 seconds to turn the display
ON or OFF. When the display is ON, press
this button once to access the OSD menu.
UP and DOWN arrows to navigate the
OSD menus. When the OSD menu
displays, press these buttons to select
a control function.
Function buttons
Adjustment buttons
Controls to adjust the selected setting.
The MINUS control decreases the selected
setting. The PLUS control increases the
selected setting. Press either button to
select a menu.
Power ON indicator
Light-emitting diode (LED) indicator that
illuminates when the display is ON and
receiving a proper video signal. The
LED blinks when the display is in power-
saving mode.
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
6 | The VitalScreen 17.4" Display
Back panel
Locking 4-pin power connector
Connect the low-voltage cable from
the power adapter to this port.
USB downstream ports (2)
USB upstream port (1)
Audio input jack
Connect peripherals (e.g., keyboard,
mouse) to these ports, if desired.2
Connect the USB cable from the
computer to this port, if desired.3
Connect the system audio lineout
to this port to listen to the system audio
on the display stereo speakers.4
Touchscreen (DB-9 serial) port
Analog (VGA) video input [port 1]
Connect the system touchscreen cable
to this port on a resistive touchscreen
display.
Connect the system VGA cable from
the computer VGA output to this port
for analog mode.
Digital (DVI) video input [port 2]
Connect the system DVI cable from
the computer DVI output to this port
for digital mode.
2
Connect USB upstream port to computer to use peripherals.
For a VitalScreen supporting S-Video and Composite Video, the
3
S-Video/Composite Video connector replaces the USB ports.
4
Do not use audio from the display speakers as the exclusive audio source in
medical applications, especially not as an alarm indicator.
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
Installing the Display
To install the VitalScreen CSR or VitalScreen CR display, first connect
the power supply unit. Next, connect the video cable. Then choose
whether to connect optional stereo speakers and touch screen.
Safety Precautions
Follow these safety precautions when connecting the display.
• Plug the power adapter into a grounded power outlet.
• Use a surge protector between the AC adapter and the electrical wall
outlet to prevent sudden current variations from reaching the display.
Connecting the AC Power to the Display
1 Plug the receptacle end of the AC power cord into the
AC power adapter.
2 Plug the power connector of the adapter into the power port on
the display. (Locate the locking 4-pin power connector on the
back panel next to the USB downstream port.)
3 Insert the power cord into a grounded wall outlet.
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
7
8 | Installing the Display
Connecting the Display to the System
1 Turn off power to the computer, camera, or other output source, and to
the display.
2 Connect the appropriate video cable from the display to the video port
on the output source.
3 Make sure the video cable connector is securely connected to the video
port on the output device.
4 Turn on the display first, then turn on the output device.
5 Set the output device to a supported resolution, if applicable.
(See “Supported CVBS and S-Video Modes” on page 16.)
6 If VGA analog is used, select the Auto-Adjust menu on the onscreen
display, if you are using VGA analog. (See “Onscreen Display Main
Menu” on page 11.) Press the PLUS or MINUS (
activate it.
/
) control to
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
Installing the Display | 9
Connecting a Video Device
Use the following instructions if you are hooking up a camera, VCR, or
other S-Video or Composite Video device, and not using the VGA or DVI
input simultaneously. These instructions apply to S-Video and Composite
Video input-equipped displays only.
1 Press the Power/Menu button until the Power ON indicator blinks.
After a moment, a No Signal Coming message appears.
2 Wait for the No Signal Coming message to disappear, approximately
3 to 5 seconds.
3 Press the Power/Menu button to display the VGA → VIDEO menu.
4 Press the PLUS or MINUS (
/
) control to enter video mode.
5 Press the UP ( ) arrow to change video modes if you are using
an alternate video source.
6 Press the PLUS or MINUS (
/
) control to select the desired
video mode.
Connecting the Optional Touch Screen
If your VitalScreen CSR or VitalScreen CR display has the optional touch
screen, connect the display 9-pin D-sub serial port to the computer 9-pin
RS-232 serial port using the cable supplied with the touchscreen package.
Next, connect the RS-232 cable to the 9-pin serial port on the back panel
of the display.
Do not operate the touch screen with sharp objects, such as a scalpel.
Sharp objects can scratch or damage the touch screen. A damaged touch
screen may pose a safety hazard.
Mounting the Display
When mounting your display, such as to a wall bracket or an
articulated swing arm, make sure the maximum length of the
screws inserted into the display mounts is 9 millimeters. Forcing
the screws deeper into the mounts and exceeding this maximum
length may damage the display.
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
10 | Installing the Display
Power Management System
The VitalScreen CSR and VitalScreen CR displays comply with the
VESA Display Power Management Signaling (DPMS) standard. This
standard provides four power-saving modes, based on the display
detecting the horizontal or vertical sync signals. This table describes
the four modes.
Mode
On
AC Input Power1
60 watts maximum
5 watts maximum
5 watts maximum
5 watts maximum
LED Status
Steady green
Blinking green
Blinking green
Off
Standby
Suspend
Off
1
Including AC adapter
When the display is in power-saving mode or detects incorrect timing,
the screen is blank and the power LED indicator blinks.
Landscape-to-Portrait Mechanical Conversion
The 17.4" display (deskstand version) has a unique feature that allows
a mechanical conversion of the display from the traditional landscape
mode to a vertical portrait mode.
Use both hands whenever you are changing the orientation of
the display.
1 Gently pull the lower half of the display toward you.
You must tilt the display upward before rotating it.
2 Rotate the display 90 degrees to left (counterclockwise) until it stops
in portrait mode.
3 Select, if necessary and/or available, the different option on the video
card, or display settings on the control panel.
landscape to portrait mode.
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
The Display Controls
Read this chapter carefully to use your VitalScreen CSR or
VitalScreen CR display efficiently and effectively.
Using the Onscreen Display
The onscreen display (OSD) makes adjusting the display settings
quick and easy. Use the OSD to adjust the brightness, contrast, volume,
position, and language for the options in the display. You can access the
OSD whenever both the computer and display are on. If the computer is
off or in power-saving mode, the OSD is inaccessible.
Onscreen Display Main Menu
Call up the OSD Main Menu by momentarily pressing the Power/Menu
button. Use the Function buttons (UP and DOWN arrows) to scroll
through the menu items. When the desired submenu displays, use
either Adjustment button (PLUS or MINUS control) to select the
submenu. Then use the Function buttons to select the desired
function and the Adjustment buttons to make the needed changes.
The available control functions are grouped into categories. The
selected mode of operation (either analog or digital) determines
the available categories.
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
11
12 | Installing the Display
Main menu
The following table describes the main menus of the onscreen display.
The Main Menus
Basic setting
Position
Change brightness, contrast
Change the display attributes
Auto-adjust
Auto-adjust the display parameters to optimum
values (not available for digital mode)
Color temperature
Miscellaneous
Adjust the color settings
Audio volume, OSD H-position, OSD V-position,
display mode, FW (firmware) version
Video
Switch to video input port. (Available with
S-Video and Composite Video display)
Language
Support six different languages: English, Dutch,
German, French, Spanish, Italian
Input port
Reset
Exit
Port 1 analog, Port 2 digital
Reset display
Close the onscreen display
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
Installing the Display | 13
Function menus
The following tables describe the function menus of the onscreen display.
Basic Setting (Available in analog and/or digital mode)
Contrast
Adjust the contrast level of the display
Analog
Digital
Brightness
Adjust the brightness of the display’s
backlight
Analog
Digital
Video level
Gamma
Auto adjusts video level when selected
Analog
Analog
Gamma curve adjustment, ranging from
0.85 to 1.15
Frame
Sets border color when native size is
selected and selected resolution is
less than default (1280 x 1024)
Analog
To main menu
Exit
Position Menu (Analog mode only)
Clock
Adjust the display pixel alignment
Phase
Adjust the screen display for focus and clarity
Appears at display resolution
Default size
Native size
H-position
V-position
H-size
Displays at computer resolution
Horizontal position adjustment (not available for digital mode)
Vertical position adjustment (not available for digital mode)
Horizontal size adjustment
V-size
Vertical size adjustment
Graphic/Text
Select either Graph or Text expansion method (Only
available in 720 x 400 and 640 x 480 resolutions)
To main menu
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
14 | Installing the Display
Color Temperature (Analog mode only)1
Color 9300
Color 6500
Color user
Set the color temperature of white to
9300 degrees Kelvin
Set the color temperature of white to
6500 degrees Kelvin
Enable "User Color" selection, and
adjust individual RGB levels
R
Adjust red contrast
Adjust green contrast
Adjust blue contrast
G
B
To main menu
1
Three sets of color temperature settings are available: two for standard
settings and one for user adjustment.
Miscellaneous Menu
Audio volume
OSD H-position
OSD V-position
Display mode
F/W version
To main menu
Exit
Audio volume adjustment
Adjust the OSD position horizontally
Adjust the OSD position vertically
Shows the display mode
Shows the firmware version
Quick adjustment functions: Analog and digital modes
For this function…
Contrast
Push this key…
Function UP (
Function DOWN (
)
Brightness
)
Audio volume
Port selection
Adjust PLUS (
)
Adjust MINUS (
)
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
Installing the Display | 15
S-Video and Composite Video Settings
These functions are active on the VitalScreen onscreen display when
the display is in S-Video or Composite Video mode.
This option is available only on the VitalScreen 17.4" CSR display.
Settings
The settings are selected with the Function buttons. Select the UP ( ) or
DOWN ( ) arrow.
Change the settings with the Adjustment buttons. Select the PLUS ( ) or
MINUS ( ) control.
Contrast
Brightness
Volume
Input
Adjust the contrast level of the display
Adjust the brightness of the display’s backlight
Adjust audio volume
Switch between S-Video and Composite Video modes
Switch between video and VGA/DVI inputs
Adjust the hue level of the display
Video → VGA
Hue
Sampling
Overscan
Reset
Change Sampling mode settings
Turn Overscan ON or OFF
Reset display S-Video or Composite Video settings
Quick adjustment functions
For this function… Push this key…
Input
Adjust MINUS ( ) twice
Audio volume
Video → VGA
Adjust PLUS (
)
Power/Menu key,1 then push Adjust PLUS ( ) or
Adjust MINUS (
)
1
Pressing and holding the Power/Menu button for more than 2 seconds turns off
the display.
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
16 | Installing the Display
Onscreen Display Lockout
Both displays incorporate an OSD lockout function that you toggle
active or inactive. Pressing three controls — Function DOWN ( ),
Adjust PLUS ( ), and Adjust MINUS ( ) — simultaneously locks out
the OSD from being enabled by the power control. Attempts to enable
the OSD result in an “OSD locked” message only. To unlock the OSD,
press the same three controls in the same manner.
Supported CVBS and S-Video Modes
Supported video formats on VitalScreen displays with S-Video and
Composite Video functionality include the following:
PAL B, G, H, I, D
NTSC M, Japan
This option is available only on the VitalScreen 17.4" CSR display.
In the table on page 17, ‘A’ signifies analog mode and ‘D’ signifies digital
mode. Also, if the input timing is close to one of the modes, generally
it can be displayed by manually adjusting the clock and/or phase from
within the OSD menu.
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
Installing the Display | 17
Supported Video Modes
Vertical
Scanning
Frequency
(Hz)
Horizontal
Scanning
Frequency
(kHz)
Sync
Polarity or
Composite
Sync (H/V)
Dot Clock
(MHz)
Operating
Mode
Item Standard
Resolution
1
2
3
4
5
6
7
8
9
NEC PC98
640x400
640X400
640x480
25.20
21.05
30.24
57.28
80.00
25.18
31.50
25.18
31.50
25.18
31.50
31.50
36.00
36.00
40.00
50.00
49.50
56.25
28.32
35.50
46.76
65.00
75.00
78.75
71.64
94.50
108.00
121.50
108.00
108.00
127.00
135.00
64.13
74.25
84.38
81.00
94.50
94.50
108.00
117.00
135.00
70.15
56.42
66.67
74.55
75.02
70.09
85.08
70.09
85.08
59.94
72.81
75.00
85.01
56.25
60.32
72.19
75.00
85.06
70.09
85.04
60.00
60.00
70.07
75.03
66.13
85.00
75.00
85.00
60.00
60.02
69.85
75.03
59.98
70.04
77.07
72.87
85.53
66.00
76.64
67.19
76.10
31.50
24.83
35.00
49.73
60.24
31.47
37.86
31.47
37.86
31.47
37.86
37.50
43.27
35.16
37.88
48.08
46.88
53.67
31.47
37.93
34.38
48.36
56.48
60.02
53.96
68.68
67.50
77.09
60.00
63.98
74.88
79.98
48.29
56.59
62.04
60.99
71.59
61.84
71.81
71.69
81.13
-/-
-/-
A/D
A
NEC PC98
MAC 13" mode
MAC 16" mode
MAC 17" mode
-/-
A/D
A/D
A/D
A/D
A/D
A/D
A/D
A/D
A/D
A/D
A/D
A/D
A/D
A/D
A/D
A/D
A/D
A/D
A/D
A/D
A/D
A/D
A/D
A/D
A/D
A/D
A/D
A/D
A
832x624
-/-
1024x768
640x350
-/-
VGA
+/-
VESA
VGA
640x350
+/-
640x400
-/+
VESA
640x400
-/+
10 VGA
11 VESA
12 VESA
13 VESA
14 VESA
15 SVGA
16 VESA
17 VESA
18 VESA
19 VGA
20 VESA
21 MEDICAL
22 XGA
23 VESA
24 VESA
25
640x480
-/-
640x480
-/-
640x480
-/-
640x480
-/-
800x600
+/+
+/+
+/+
+/+
+/+
-/+
800x600
800x600
800x600
800x600
720x400
720x400
-/+
1024x512
1024x768
1024x768
1024x768
1024x768
1024x768
1152x864
1152x864
1280x960
1280x1024
1280x1024
1280x1024
1024x768
1024x768
1024x768
1024x800
1024x800
1152x900
1152x900
1280x1024
1280x1024
-/-
-/-
-/-
+/+
+/+
+/+
+/+
+/+
+/+
+/+
+/+
+/+
H+V
H+V
H+V
H+V
H+V
H+V
H+V
H+V
H+V
26 VESA
27 VESA
28 VESA
29 VESA
30 VESA
31 VESA
32 VESA
33 SUN
34 SUN
35 SUN
36 SUN
37 SUN
38 SUN
39 SUN
40 SUN
41 SUN
A
A
A
A
A
A
A
A
A
A
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
Technical Information
VitalScreen 17.4" CSR/CR
Display panel
Specification
17.4-inch (442-mm) SXGA active matrix LCD
Full color supporting 8-bits/color
Display colors
Dimensions (W x H x D)
Landscape mode 18" x 18" x 8.5" (457 mm x 457 mm x 216 mm)
Portrait mode 15" x 19.5" x 8.5" (381 mm x 495 mm x 216 mm)
Weight
20 lb (9 kg)
Display area (W x H)
Response time
Viewing angle
Contrast ratio
Brightness
13.6" x 10.9" (345.6 mm x 276.48 mm)
25 milliseconds Wht>Blk @ 25 milliseconds max.
160 degrees (horizontal or vertical)
400:1 in dark room (0 lux) typical
Non-touch 200 cd/m2 typical
Resistive touch 176 cd/m2 typical
Pixel pitch (W x H)
Reliability
0.297 mm x 0.297 mm
Monitor 30,000 hours mean time between failure (MTBF)
Backlight 50,000 hours to reach 50% of initial brightness
Scanning frequency
Power consumption
Analog Horizontal
Vertical
Digital Horizontal
Vertical
24 to 81 kHz
56 to 85 Hz
38.6 to 60 kHz
50 to 75 Hz
60 watts maximum
<5 watts in standby or off mode
Power supply
Audio
12 volts / 5 amps, 60 watts
Stereo speakers with integral amp.
(min. 1W/channel, <1% distortion)
Temperature
Humidity
Operating 0 to 40 degrees Celsius
Nonoperating -20 to 60 degrees Celsius
Operating 10 to 90 percent relative humidity (noncondensing)
Nonoperating 10 to 90 percent relative humidity (noncondensing)
Altitude
Operating 0 to 8000 ft (2400 m)
Nonoperating 0 to 40,000 ft (12,200 m)
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
19
Troubleshooting
PROBLEM: Display is unclear and unstable
This procedure is for users of analog VGA.
This LCD device comes pre-adjusted with standard VGA timing. Due to
output differences among various VGA cards, you may initially experience
an unclear and unstable display when a new display mode or new VGA
card is detected. To correct the problem, follow these steps:
1 Apply the Auto-Adjust option in the OSD menu for the display to
adjust automatically to the video signal.
2 If the picture remains unstable, consider manual adjustment of the
clock and phase (in the OSD menu of the display). These adjustments
are not recommended for nontechnical users.
3 If the system still does not function properly, get help from technical
support at your system provider.
PROBLEM: No image appears on LCD screen
If no image appears on the LCD screen, follow these steps:
1 Make sure the power indicator on the display is illuminated, all
connections are secure, and the system is running on a supported
video timing mode.
2 If the power LED is not illuminated, make sure the AC power
connector is securely connected. If the AC adapter has an LED,
verify that the LED is illuminated. If it is not, contact your dealer
for assistance.
3 Turn the display off and then turn it back on.
4 Connect your system to another Planar 17.4 display, if one is available.
If the system functions properly with the alternate display but not
with the original display, and the original display’s power LED is
blinking, the output timing of the computer’s video board may be out
of the display’s synchronous range. Change to an alternate mode
(1280 x 1024, or less), or connect to an alternate video source and
repeat steps 1 and 2.
5 Ensure that the computer’s video port is enabled (DVI or VGA).
This is a function of the video board in the user computer system.
See your system’s video board documentation for instructions on
how to enable the video port.
6 If the system does not function with either display, get help from
technical support at your system provider.
20
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
21
Index
A
M
adjustment functions, quick, 14, 15
assistance, technical, 24
main menu, onscreen display, 11, 12
mechanical conversion, landscape to
portrait, 10
menu
function, 13
main, 11, 12
B
back panel, 6
cleaning instructions, xi
components, identifying, 4
connecting
AC power to display, 7
display to system, 8
optional touch screen, 9
video device, 9
controls, display, 11
conversion, mechanical, 10
customer support, 24
CVBS and S-video modes, 16
O
onscreen display
function menu, 13
lockout, 16
main menu, 11, 12
using, 11
optional touch screen, connecting, 9
ordering information, 25
P
power management system, 10
product symbols, xii
D
display
Q
components, 4
quick adjustment functions, 14, 15
connecting AC power, 7
connecting to system, 8
controls, 11
R
repair service, 23, 24
S
installing, 7
safety instructions, x
selecting workspace, 3
service, repair, 23, 24
screen, LCD, 4
specifications, display, 19
supported video modes, 16
symbol explanations, xii
onscreen lockout, 16
onscreen main menu, 11, 12
description of, 1, 2
specifications, 19
troubleshooting, 20
unpacking, 3
using onscreen, 11
disposal information, xi
T
technical
F
assistance, 24
front panel, 5
information, 19
function menu, 13
touch screen (optional), connecting, 9
troubleshooting, 20
functions, quick adjustment, 14, 15
I
U
information
disposal, xi
ordering, 25
technical, 19
installing display, 7
instructions
cleaning, xi
safety, x
unpacking display, 3
using onscreen display, 11
V
video
device, connecting, 9
modes, supported, 16
settings, S-video and composite, 15
L
W
landscape-to-portrait conversion, 10
LCD screen, 4
lockout, onscreen display, 16
warranty, 23
workspace, selecting, 3
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
23
Description of Warranty
Planar Systems, Inc. (Planar) warrants that the goods sold hereunder
will be free of defects in materials and workmanship, and such goods
will substantially conform to the specifications furnished by Planar,
and to any drawings or specifications furnished to Planar by the Buyer
if approved by Planar. This warranty shall be effective only if Planar
receives notice of such defect or nonconformance during the period of
the warranty. Planar’s sole and exclusive liability for breach of warranty
shall be, at the company’s option, to repair or replace the Planar
product(s) with refurbished units or provide a credit to Buyer in
the amount of the purchase price.
Commencement and duration of warranty
The warranty period begins on the date of shipment from Planar.
The goods sold hereunder are warranted for a period of 36 months
from date of shipment unless otherwise agreed to by Buyer and
Planar. No extension of the warranty will be given during the time
the goods are in the possession of Planar.
Place of repair or replacement
To obtain service under this warranty, Buyer must notify Planar of the
defect before expiration of the warranty period and request a “Return
Material Authorization Number (RMA).” If the configuration has been
modified in any manner, the product must be returned to its original
configuration before any warranty service will be performed by Planar.
No goods are to be returned to Planar without prior authorization.
Buyer will be responsible for packaging and shipping the defective
goods to the appropriate Planar service facility. For North America,
the service facility is located in Beaverton, Oregon; for Europe, the
service facility is located in Espoo, Finland.
Limitation of warranty
The foregoing warranty shall not apply to defects resulting from
(a) improper or inadequate maintenance by Buyer; (b) unauthorized
modification of the goods; (c) operations of the goods outside the
environmental specifications of the goods; (d) neglect, misuse, or
abuse of the goods; or (e) modification or integration with other
goods not covered by the Planar warranty when such modification
or integration increases the likelihood of damage to the goods.
THE WARRANTY IS GIVEN BY Planar IN LIEU OF ANY OTHER
WARRANTIES, EXPRESSED OR IMPLIED. Planar DISCLAIMS ANY
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE. Planar’s RESPONSIBILITY TO
REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE
AND EXCLUSIVE REMEDY PROVIDED TO THE BUYER FOR
BREACH OF THIS WARRANTY. Planar WILL NOT BE LIABLE
FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES IRRESPECTIVE OF WHETHER Planar HAS ADVANCE
NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
24
The warranty set forth above shall not be enlarged, diminished, or
affected by, and no obligation or liability shall arise from, Planar, any
authorized dealer, or any other person’s rendering of technical advice,
assistance, or services in connection with the Buyer’s order of the goods
furnished hereunder. The Buyer is not relying on skill or judgment of
Planar to select or furnish suitable goods.
Installation
Planar makes no warranty with respect to any installation of Planar
product(s) by Planar, any authorized dealer, or any other person.
Technical assistance
In North America, call (503) 748-1100 between 8 A.M. and 5 P.M. Pacific
time, Monday through Friday, or send a description of your technical
issues and e-mail address to tech_support@planar.com.
In Europe, call +358 9 420 01 between 8 A.M. and 4 P.M. Finnish
time (Eastern European time), Monday through Friday, or send
a description of your technical issues and e-mail address to
intltech_support@planar.com.
Repair service
In North America, call Planar at (503) 748-1100 between 8 A.M. and
4 P.M. Pacific time, Monday through Friday, or fax your request to
(503) 748-1493. You will need the unit’s serial number and a brief
description of the problem to receive an RMA number.
In Europe, call Planar Customer Service at +358 9 420 01 between 8 A.M.
and 4 P.M. Eastern European time, Monday through Friday, or fax your
request to +358 9 420 0200. You will need the unit’s serial number and
a brief description of the problem to receive an RMA number.
To protect Planar employees from potential health hazards, Planar
requires that the RMA product be disinfected before returning to
Planar for service. Any product not cleaned prior to shipment will
be returned to the customer.
Returns are not accepted without an assigned RMA number.
In-transit damage is not covered by the warranty. Insure your shipment.
Planar will only pay for the return shipment by surface transportation.
It is the responsibility of the sender to prepay transportation charges.
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
25
Ordering Information
VitalScreen CSR
Part Number
VS17.4SXAD 17.4-inch SXGA VitalScreen Medically Certified
996-0497-00
Display (non-touch) with desk stand and U.S. power cord
VS17.4SXAD 17.4-inch SXGA VitalScreen Medically
Certified Display (non-touch) with desk stand and
European power cord
996-0497-01
996-0497-02
996-0497-03
996-0498-00
996-0498-01
996-0498-02
996-0498-03
996-0533-00
996-0533-01
996-0533-02
996-0533-03
996-0534-00
996-0534-01
996-0534-02
996-0534-03
VS17.4SXAD 17.4-inch SXGA VitalScreen Medically
Certified Display (non-touch) with standard mounting
(VESA compatible, 75 mm) and U.S. power cord
VS17.4SXAD 17.4-inch SXGA VitalScreen Medically
Certified Display (non-touch) with standard mounting
(VESA compatible, 75 mm) and European power cord
VS17.4SXAD-TR 17.4-inch SXGA VitalScreen Medically
Certified Display (resistive touch) with desk stand and
U.S. power cord
VS17.4SXAD-TR 17.4-inch SXGA VitalScreen Medically
Certified Display (resistive touch) with desk stand and
European power cord
VS17.4SXAD-TR 17.4-inch SXGA VitalScreen Medically
Certified Display (resistive touch) with standard mounting
(VESA compatible, 75 mm) and U.S. power cord
VS17.4SXAD-TR 17.4-inch SXGA VitalScreen Medically
Certified Display (resistive touch) with standard mounting
(VESA compatible, 75 mm) and European power cord
VS17.4SXADV SXGA 17.4-inch video-equipped VitalScreen
Medically Certified Display with desk stand and U.S. power
cord (non-touch)
VS17.4SXADV SXGA 17.4-inch video-equipped VitalScreen
Medically Certified Display with desk stand and European
power cord (non-touch)
VS17.4SXADV SXGA 17.4-inch video-equipped VitalScreen
Medically Certified Display with universal VESA mounting
solution and U.S. power cord (non-touch)
VS17.4SXADV SXGA 17.4-inch video-equipped VitalScreen
Medically Certified Display with universal VESA mounting
solution and European power cord (non-touch)
VS17.4SXADVTR SXGA 17.4-inch video-equipped
VitalScreen Medically Certified Display with desk stand and
U.S. power cord (resistive touch)
VS17.4SXADVTR SXGA 17.4-inch video-equipped
VitalScreen Medically Certified Display with desk stand and
European power cord (resistive touch)
VS17.4SXADVTR SXGA 17.4-inch video-equipped
VitalScreen Medically Certified Display with universal VESA
mounting solution and U.S. power cord (resistive touch)
VS17.4SXADVTR SXGA 17.4-inch video-equipped
VitalScreen Medically Certified Display with universal VESA
mounting solution and European power cord (resistive touch)
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
26
VitalScreen CR
Part Number
CM17.4SXAD 17.4 SXGA VitalScreen CR (non-touch) with
desk stand and U.S. power cord
996-0514-00
CM17.4SXAD 17.4 SXGA VitalScreen CR (non-touch) with
desk stand and European power cord
996-0514-01
996-0514-02
CM17.4SXAD-TR 17.4 SXGA VitalScreen CR (non-touch)
with standard mounting (VESA compatible, 75 mm) and
U.S. power cord
CM17.4SXAD-TR 17.4 SXGA VitalScreen CR (non-touch)
with standard mounting (VESA compatible, 75 mm) and
European power cord
996-0514-03
CM17.4SXAD-TR 17.4 SXGA VitalScreen CR (resistive
touch) with desk stand and U.S. power cord
996-0515-00
996-0515-01
996-0515-02
CM17.4SXAD-TR 17.4 SXGA VitalScreen CR (resistive
touch) with desk stand and European power cord
CM17.4SXAD-TR 17.4 SXGA VitalScreen CR (resistive
touch) with standard mounting (VESA compatible, 75 mm)
and U.S. power cord
CM17.4SXAD-TR 17.4 SXGA VitalScreen CR (resistive
touch) with standard mounting (VESA compatible, 75 mm)
and European power cord
996-0515-03
Items Included with All Display Products
Part Number
Cable, VGA-VGA, 2 m, white, smooth surface (analog)
with audio
903-0293-00
Cable, DVI-DVI, 2 m, white, smooth surface with audio
903-0292-00
020-0168-00
17.4" VitalScreen CSR and VitalScreen CR
operations manuals (English)
3 m S-Video/CVBS cable (VS17.4SXADV only)
3 m audio cable (VS17.4SXADV only)
Available Cables and Accessories
100-mm VESA mounting plate
903-0308-00
903-0310-00
Part Number
501-0415-00
903-0251-00
903-0169-00
903-0233-00
902-0238-00
501-0380-00
European medical grade power cord, 1.5 m
U.S. medical grade power cord, 3 m
Touchscreen cable, 2 m, white, smooth surface
12 V medical grade power supply
Planar desk stand for 17.4" display
VS17.4SXAD / CM17.4SXAD (020-0168-00B)
North and South America Sales
Europe and Asia-Pacific Sales
Planar Systems, Inc.
Planar Systems, Inc.
1195 NW Compton Drive
Beaverton, OR 97006-1992
+1 (503) 748-1100 phone
+1 (503) 748-1493 fax
Olarinluoma 9, P.O. Box 46
FIN-02201 Espoo, Finland
+358 9 420 01 phone
+358 9 420 0200 fax
|