Pelco Security Camera PT7700 User Manual

WARNING!  
Warning! When lifting, transporting, or un-  
packing the PT7700 Series pan/tilt systems,  
DO NOT use the camera enclosure as a  
handle. Severe damage to the unit can occur.  
C997M  
®
3500 Pelco Way, Clovis, CA 93612-5699 • (559) 292-1981 • (800) 289-9100  
• FAX (800) 289-9150  
 
CONTENTS  
Section  
Page  
1.0 GENERAL ..................................................................................................3  
1.1 IMPORTANT SAFEGUARDS AND WARNINGS ...............................3  
2.0 DESCRIPTION ..........................................................................................4  
2.1 MODELS ............................................................................................4  
2.2 CERTIFICATIONS .............................................................................4  
3.0 INSTALLATION ..........................................................................................5  
3.1 MOUNTING .......................................................................................5  
3.2 CAMERA/LENS INSTALLATION .......................................................5  
3.3 WIRING .............................................................................................7  
3.4 TESTING SYSTEM AND ADJUSTING LIMIT STOPS......................10  
4.0 OPERATION ............................................................................................. 11  
5.0 TROUBLESHOOTING ..............................................................................12  
6.0 MAINTENANCE ........................................................................................13  
7.0 EXPLODED ASSEMBLY DIAGRAMS ......................................................15  
8.0 SPECIFICATIONS ....................................................................................20  
9.0 WARRANTY AND RETURN INFORMATION ...........................................24  
LIST OF ILLUSTRATIONS  
Figure  
Page  
1
2
3
4
5
6
7
8
9
PT7700 Series Input Wiring Diagram ................................................8  
PT7700 Series Connector .................................................................9  
Tilt Limit Stop Adjustment .................................................................10  
Pan Adjustments and Lubrication .....................................................14  
Tilt Adjustments and Lubrication .......................................................14  
Exploded Assembly Diagram for Blower and Circuit Board ..............15  
Exploded Assembly Diagram for Heaters and Circuit Board ............17  
Wiring Diagram for Enclosure Circuit Board .....................................18  
Component Locations for Enclosure Circuit Board ...........................19  
Layout of Traces on Enclosure Circuit Board ...................................19  
Dimension Drawing ...........................................................................23  
10  
11  
LIST OF TABLES  
Table  
Page  
A
B
Parts List (Figure 6) ..........................................................................16  
Parts List (Figure 7) ..........................................................................17  
REVISION HISTORY  
Manual #  
Date  
Comments  
C397M  
C397M  
8/96  
8/97  
Original version  
Completely revised manual. Added models and revised  
pin assignments in Figure 2 per ECR #0927.  
Removed options. Added certifications. Changed pagination.  
4/98  
2
Pelco Manual C397M (4/98)  
 
1.0 GENERAL  
1.1 IMPORTANT SAFEGUARDS AND WARNINGS  
Prior to installation and use of this product, the following WARNINGS should be  
observed.  
1. Installation and servicing should only be done by Qualified Service Personnel  
and conform to all Local codes.  
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or  
6P enclosure, it is designed for indoor use only and it must not be installed  
where exposed to rain and moisture.  
3. The weight of the camera/lens and enclosure shall not exceed 75 lbs.  
(34.02 kg).  
4. Only use replacement parts recommended by Pelco.  
5. After replacement/repair of this unit’s electrical components, conduct a resis-  
tance measurement between line and exposed parts to verify the exposed  
parts have not been connected to line circuitry.  
6. The installation method and materials should be capable of supporting four  
(4) times the weight of the enclosure, pan/tilt, camera and lens combination.  
The product and/or manual may bear the following marks:  
This symbol indicates that dangerous voltage constituting a  
risk of electric shock is present within this unit.  
This symbol indicates that there are important operating and  
maintenance instructions in the literature accompanying this  
unit.  
CAUTION:  
RISK OF  
ELECTRIC SHOCK.  
DO NOT OPEN.  
CAUTION:  
TO REDUCE THE RISK OF ELECTRICAL SHOCK,  
DO NOT REMOVE COVER. NO USER-  
SERVICEABLE PARTS INSIDE. REFER SERVICING  
TO QUALIFIED SERVICE PERSONNEL.  
Please thoroughly familiarize yourself with the information  
in this manual prior to installation and operation.  
Pelco Manual C397M (4/98)  
3
 
2.0 DESCRIPTION  
The PT7700 systems combine an environmental camera enclosure, pan/tilt as-  
sembly, and receiver/driver into a single unit that you can install indoors or out-  
doors. You can install 2/3-inch (1.69 cm) and 1-inch (2.54 cm) format cameras with  
either fixed focal length lenses or motorized zoom lenses. An adjustable camera  
sled will accommodate different sizes of cameras and lenses.  
2.1 MODELS  
PT7723RX-1  
Pan/tilt, CX9115RX Coaxitron® receiver/driver, and EH5723-1  
23-inch (54 cm) enclosure. 120 VAC input. Thermostatically  
controlled heater and blower.  
PT7723RX-1/PP  
PT7723RX-3  
PT7723RX-1 with preset positioning capabilities and alarm  
outputs.  
Pan/tilt, CX9115RX Coaxitron® receiver/driver, and EH5723-1  
23-inch (54 cm) enclosure. 230VAC input. Thermostatically  
controlled heater and blower.  
PT7723RX-3/PP  
PT7729RX  
PT7723RX-3 with preset positioning capabilities and alarm  
outputs.  
Pan/tilt, CX9115RX Coaxitron® receiver/driver, and EH5729  
29-inch (74 cm) environmental camera enclosure. 120 VAC input.  
PT7729RX with thermostatically controlled heater and blower.  
PT7729RX-1 with preset positioning capabilities and alarm  
outputs.  
PT7729RX-1  
PT7729RX-1/PP  
PT7729RX-1/SL  
PT7729RX-3  
PT7729RX-1 with 360° pan rotation.  
Pan/tilt, CX9220RX Coaxitron® receiver/driver, and EH5729-3  
29-inch (74 cm) enclosure. 230 VAC input. Thermostatically  
controlled heater and blower.  
PT7729RX-3/PP  
PT7723WX-1  
PT7729RX-3 with preset positioning capabilities and alarm  
outputs.  
Pan/tilt, WX8115RX Wiretron receiver/driver, and EH5723-1  
23-inch (54 cm) enclosure. 120 VAC input. Thermostatically  
controlled heater and blower.  
PT7729WX  
Pan/tilt, WX8115RX Wiretron receiver/driver, and EH5729  
29-inch (74 cm) environmental camera enclosure. 120 VAC input.  
PT7729WX with thermostatically controlled heater and blower.  
Pan/tilt, WX8220RX Wiretron receiver/driver, and EH5729-3  
29-inch (74 cm) enclosure. 230 VAC input. Thermostatically  
controlled heater and blower.  
PT7729WX-1  
PT7729WX-3  
2.2 CERTIFICATIONS  
The products identified below have been tested and certified for agency compli-  
ance as noted.  
Agency Compliance Certification  
Model  
CE  
FCC  
UL  
X
CSA/cUL  
PT7723RX-1  
PT7723RX-1/PP  
PT7729RX-1  
PT7729RX-1/PP  
PT7729RX-1/SL  
PT7723WX-1  
PT7729WX  
X
X
X
X
X
X
PT7729WX-1  
X
Applicable CE, FCC, UL, and CSA/cUL directives/standards:  
UL Listed to UL2044  
4
Pelco Manual C397M (4/98)  
 
3.0 INSTALLATION  
CAUTION: When unpacking, transporting, or lifting the PT7700 Series systems, DO NOT use  
the camera enclosure as a handle. Severe damage to the unit can occur.  
NOTE: To insure proper wiring and operation of your equipment, it is recommended that you test the PT7700  
system and its controller in your facility before installing them in the field. Refer to Sections 3.2 through 3.4.  
3.1 MOUNTING  
Attach the base of the pan/tilt system to a flat surface. If you use a wall or pedestal  
CAUTION: The PT7700  
mount, follow the instructions that are provided with the mount.  
systems are designed to op-  
erate in an upright position  
Make sure the mounting surface can support four (4) times the weight of the pan/tilt  
only. Do not mount the sys-  
tems horizontally or in an in-  
verted position.  
system. Refer to section 8.0, “Specifications,” for unit weights (excluding camera/  
lens).  
Proceed to Section 3.2, CAMERA/LENS INSTALLATION.  
3.2 CAMERA/LENS INSTALLATION  
1. Open the enclosure lid and remove the camera sled from the rail:  
a. Loosen the screws.  
b. Slide the sled so that the screws are in the large part of the mounting  
slots.  
c. Remove the sled.  
d. Remove the parts tied to the sled.  
2. All Models Except the PT7729RX and PT7729WX - If you are installing the  
pan/tilt system in a marine or high-moisture environment, make the following  
modifications to your enclosure:  
Refer to Figure 6 in Section 7.0, “Exploded Assembly Diagram,” for an ex-  
ploded assembly diagram of the blower assembly.  
a. Remove the plastic cover over the power supply section of the circuit  
board.  
b. Disconnect the electrical plug from the fan.  
c. Remove the three screws that secure the fan plate and fan to the enclosure.  
d. Remove the four screws that secure the fan to the fan plate.  
e. Turn the fan around so that it blows toward the viewing window (refer to  
the arrows on the fan).  
f.  
Reinstall the fan on the fan plate.  
g. Reinstall the fan plate and fan in the enclosure.  
h. Reconnect the electrical plug on the fan.  
i.  
Replace the plastic cover.  
Pelco Manual C397M (4/98)  
5
 
j.  
On the bottom of the enclosure, remove the vent grill and filters at the  
front of the enclosure. Replace the grill with one of the vent cover plates  
that was attached to the camera sled as loose equipment.  
k. On the bottom of the enclosure, attach the other vent cover plate over  
the grill at the rear of the enclosure.  
3. Mount the camera/lens to the sled with the 1/4-20 Phillips-head screws that  
are provided in the parts bag. You can mount the camera to either side of the  
sled for proper elevation of the camera inside the enclosure.  
4. Install the sled and camera/lens in the enclosure:  
a. If the camera’s lens is adjustable, extend the lens to its maximum length.  
b. Place the sled over the mounting screws in the enclosure.  
c. Slide the sled forward until the camera’s lens almost touches the window.  
d. Tighten the screws to secure the camera sled to the enclosure.  
5. Connect the video cable in the enclosure to the video output connection on  
the camera.  
6. If your camera has a motorized zoom lens control, connect or wire the camera’s  
lens control to the LENS or LENS CONTROL connector on the circuit board.  
Refer to Figure 1 to see where to connect different lens connector options.  
7. Wire power from the circuit board to the camera. There are two ways to con-  
nect power (refer to Figure 1):  
NOTE: If the AC power input to your  
PT7700 unit is 120 VAC, the camera  
must use 120 VAC. If the power in-  
put is 230 VAC, the camera must use  
230 VAC.  
a. A three-pin plug with leads is supplied as loose equipment. Connect the  
leads from the plug to the camera as follows:  
Brown - AC HI  
Blue - AC NT  
Green - Ground  
Remove the plastic cover over the power supply section of the circuit  
board.  
Connect the plug to the CAM1 socket on the circuit board.  
Replace the plastic cover.  
or  
b. If your pan/tilt system uses 120 VAC and you ordered the optional 120 VAC  
electrical outlet accessory (O/I-OUTLET), connect the 120 VAC plug to the  
camera. Connect the three-pin plug to CAM1 (remove the plastic cover over  
the circuit board and replace the cover after you plug in the connector).  
8. Adjust the focus and iris on the camera, if necessary.  
9. Close the enclosure lid.  
Proceed to Section 3.3, WIRING.  
6
Pelco Manual C397M (4/98)  
 
3.3 WIRING  
1. Route the six-foot power/video/control cable through the wall or pedestal mount  
if applicable.  
2. Connect the end of the cable with the 16-pin connector to the mating connec-  
tor in the base of the pan/tilt unit.  
3. Connect the other end of the cable as follows:  
a. Connect the coax cable to the video input of the controller.  
b. For models PT7729WX, PT7729WX-1, PT7723WX-1 and PT7729WX-3,  
connect the Wiretron control wires (refer to Figure 2).  
c. For models PT7729RX-1/PP and PT7729RX-3/PP, connect the alarm  
outputs (cable not supplied). Refer to Figure 2.  
d. Plug the power cord into either 120 VAC or 230 VAC, depending on your  
model.  
Proceed to Section 3.4, TESTING SYSTEM AND ADJUSTING LIMIT STOPS.  
Pelco Manual C397M (4/98)  
7
 
Fige 1. PT7700 Series Input Wiring Diagram  
8
Pelco Manual C397M (4/98)  
 
PIN  
FUNCTION  
COLOR  
RED  
2
COAX CORE  
COAX SHIELD  
GROUND  
AUX COMMON  
AUX1  
PT7729RX  
PT7723RX-1  
PT7729RX-1  
PT7729RX-3  
PT7729RX-1/SL  
Base Connector  
Pin Assignments  
4
BLK  
8
GRN  
10  
11  
12  
13  
15  
16  
WHT/GRN  
ORG  
AUX2  
YEL  
AUX3  
BLU  
AC NEUTRAL  
AC HIGH  
WHT (2X)  
BLK (2X)  
PIN  
FUNCTION  
COLOR  
RED  
2
COAX CORE  
4
COAX SHIELD  
BLK  
8
GROUND  
GRN  
PT7729WX  
9
WIRETON INPUT SIGNAL HIGH  
BRN/WHT  
WHT/GRN  
ORG  
PT7723WX-1  
PT7729WX-1  
PT7729WX-3  
Base Connector  
Pin Assignments  
10  
11  
12  
13  
14  
15  
16  
AUX COMMON  
AUX1  
AUX2  
YEL  
AUX3  
BLU  
WIRETRON INPUT SIGNAL LOW  
AC NEUTRAL  
BLK/WHT  
WHT (2X)  
BLK (2X)  
AC HIGH  
PIN  
FUNCTION  
COLOR  
RED  
2
4
COAX CORE  
COAX SHIELD  
GROUND  
BLK  
8
GRN  
15  
16  
1
AC NEUTRAL  
AC HIGH  
WHT (2X)  
BLK (2X)  
PT7729RX-1/PP  
PT7729RX-3/PP  
With Alarm Outputs  
Base Connector  
Pin Assignments  
ALARM #1  
ALARM #2  
ALARM #3  
ALARM #4  
ALARM #5  
ALARM #6  
ALARM #7  
ALARM #8  
3
5
6
7
10  
11  
12  
13  
EXTERNAL ALARMING OUTPUT (ACTIVE LO)  
ALARM COMMON IS CHASSIS GROUND  
Figure 2. PT7700 Series Connector  
Pelco Manual C397M (4/98)  
9
 
3.4 TESTING SYSTEM AND ADJUSTING LIMIT STOPS  
To test the system and adjust the limit stops:  
WARNING: Never remove  
the limit stops. Do not ad-  
just the limit stops while the  
unit is moving. You may in-  
jure yourself or damage the  
unit.  
1. Loosen the two pan limit stops at the base of the pan/tilt.  
2. Turn on power.  
3. Test the system by moving the pan/tilt to the left, right, up and down. Do not  
move the pan/tilt very far as the limit stops are not set yet. All you want to do is  
verify that the motors work. Also verify that the camera functions properly.  
4. Pan the unit to the right to the desired right pan limit.  
5. Move the right pan limit stop until it touches the pan limit switch actuator.  
Continue pushing the stop until the actuator clicks, indicating the switch has  
opened. Lock the stop in place.  
6. Pan the unit to the left to the desired left pan limit.  
7. Move the left pan limit stop until it touches the pan limit switch actuator. Con-  
tinue pushing the stop until the actuator clicks, indicating the switch has opened.  
Lock the stop in place.  
8. Remove the four screws from the right side cover of the pan/tilt.  
NOTE: The tilt limit stops are factory  
set for 0° and -90° from the horizon.  
9. Refer to Figure 3 and loosen the recessed set screws on the up and down  
limit stop collars attached to the tilt shaft.  
10. Tilt the unit up to the desired upward limit.  
11. Turn the up limit stop collar until it touches the tilt limit switch actuator. Con-  
tinue turning the stop until the actuator clicks, indicating the switch has opened.  
Lock the collar in place.  
12. Tilt the unit down to the desired downward limit.  
13. Turn the down limit stop collar until it touches the tilt limit switch actuator.  
Continue turning the stop until the actuator clicks, indicating the switch has  
opened. Lock the collar in place.  
14. Replace the side cover.  
15. The installation is complete.  
Figure 3. Tilt Limit Stop Adjustment  
10  
Pelco Manual C397M (4/98)  
 
4.0 OPERATION  
Refer to the manual for your control equipment for operating the pan/tilt system.  
If your enclosure has a thermostatically controlled blower, the thermostat is set to  
turn the fan on between 77° and 93°F (25° and 34°C) and to turn the fan off be-  
tween 62° and 78°F (17° and 26°C).  
If your enclosure has thermostatically controlled heaters or defroster, the thermo-  
stat is set to turn them on between 42° and 58°F (6° and 14°C) and to turn them off  
between 72° and 88°F (22° and 31°C).  
Pelco Manual C397M (4/98)  
11  
 
5.0 TROUBLESHOOTING  
Fuses are located inside the left cover of the pan/tilt unit. Fuses F1 (mother board)  
and F2 (camera) are 2/10-ampere, slow-blow fuses. F3 (pan/tilt) is a 1-ampere,  
slow-blow fuse. To order fuses F1 and F2, specify the part number FUS2/10SB. To  
order fuse F3, specify the part number FUS1SB.  
If you need to return the pan/tilt system and you can not place the camera enclo-  
sure in a horizontal position, remove three of the four Allen bolts that attach the  
enclosure to the tilt shaft. This will allow movement without damage to the gear  
train assembly components.  
Figures 6-7 and Tables A-B show exploded assembly diagrams and parts lists for  
the blower and heaters, if your model is equipped with them.  
Figures 8-10 show the wiring, component locations, and layout of traces for the  
circuit board in the enclosure.  
12  
Pelco Manual C397M (4/98)  
 
6.0 MAINTENANCE  
Perform the following maintenance at six-month (or more often in harsh environ-  
ments) intervals to prolong the operational life and appearance of the equipment.  
Window and Filters  
1. Clean the window with a mild nonabrasive detergent in water and a soft cloth  
to maintain picture clarity.  
2. If your enclosure has a blower, clean the foam filters as follows:  
a. On the bottom front of the enclosure, remove the two screws in the vent grill.  
b. Remove the vent grill and take out the filters.  
c. Clean the filters with warm water and mild detergent, dry thoroughly, and  
replace them in the grill.  
d. Reinstall the vent grill.  
To order replacement filters, use the part number EH550010045.  
Pan Adjustments and Lubrication  
3. Tilt the enclosure so that the front points downward.  
4. Remove the four screws at the rear, just above the base, of the pan/tilt unit.  
5. Lift up the lid slightly and push it forward to free the lip at the front of the lid.  
6. Check the tension of the pan drive chain. A movement of 1/32" to 3/32" in the  
chain is acceptable. To adjust the chain:  
a. Refer to Figure 4. Loosen the four screws (A - two shown) that secure the  
motor/gearbox to the mounting frame.  
b. Use a screwdriver to pry at B to apply tension to the chain.  
c. Tighten the screws.  
7. If necessary, tighten the nut at C to remove any endplay in the worm (E).  
8. Lubricate the pan gears and chain assembly with a high quality grease ca-  
pable of withstanding temperatures from -50° to 170° F (-46° to 77° C):  
a. Liberally apply grease to the chain and sprockets (D), worm (E), and  
worm gear (behind worm).  
b. Pan the unit to spread the grease uniformly on the parts.  
c. Apply additional grease if necessary.  
9. Replace the lid over the pan housing.  
Pelco Manual C397M (4/98)  
13  
 
Tilt Adjustments and Lubrication  
10. Remove the plastic cover on the right side of the pan/tilt unit.  
11. Refer to Figure 5. Verify that the worm (B) is fully seated in the worm gear (A).  
If it is not, turn the two nuts (C) to lift the worm. Tighten the two nuts at (D).  
12. If necessary, tighten the nut at E to remove any endplay in the worm (B).  
13. If you can move the enclosure up and down, but the worm gear (A) does not  
move, push pin H further into the tilt shaft to eliminate movement.  
14. Lubricate the tilt gears and chain assembly with a high quality grease capable  
of withstanding temperatures from -50° to 170° F (-46° to 77° C):  
a. Liberally apply grease to the chain and sprockets (J), worm (B), and worm  
gear (A).  
b. Tilt the unit to spread the grease uniformly on the parts.  
c. Apply additional grease if necessary.  
15. Replace the cover over the tilt housing.  
Figure 4. Pan Adjustments and Lubrication  
H
A
B
E
D
C
G
F
D
C
J
Figures 5. Tilt Adjustments and Lubrication  
14  
Pelco Manual C397M (4/98)  
 
7.0 EXPLODED ASSEMBLY DIAGRAMS  
B
11  
C
9
E
10  
B
C
B
A
8
B
12  
A
F
G
7
H
6
5
4
2
1
SCREWS COME WITH  
BLANKING PLATE  
Figure 6. Exploded Assembly Diagram for Blower and Circuit Board  
Pelco Manual C397M (4/98)  
15  
 
Table A. Parts List (Figure 6)  
Item  
Qty  
Description  
Part Number  
1
2
4
5
6
7
8
9
1
2
1
1
2
1
1
1
1
1
1
1
Vent Grill  
57004005COMP  
EH550010045  
EH450010256  
PCB9000276ASSY  
EH47004029COMP  
EH470010019  
WIR432000  
Foam Filter  
Circuit Board Insulator  
Circuit Board  
Power Supply Barrier  
Power Supply Barrier Cover  
Fan Wire Cord with Plug  
Fan Tube, 230 VAC  
Fan Tube, 120 VAC  
Fan Plate  
ED210015  
EH18013  
10  
11  
12  
57004010COMP  
570010007  
Standoff, 3.375" Length  
Connector Plug  
CON1-480318-0  
A
B
C
E
F
3
8
2
4
2
2
2
Screw, 6-32 x 3/8", Pan Head, Phillips  
Internal Tooth Lock Washer, #6  
Flat Washer, #6  
ZH6-32X.375SPP  
ZH6LWSIS  
ZH148X375X32  
ZH6-32X.375CS  
ZH4-40X.250SPP  
ZH4LWSSL  
Cap Screw, 6-32 x 3/8", Allen Socket Head  
Screw, 4-40 x 1/4", Pan Head, Phillips  
Split Lock Washer, #4  
G
H
Circuit Board Grounding Clip  
570010004  
16  
Pelco Manual C397M (4/98)  
 
Figure 7. Exploded Assembly Diagram for Heaters and Circuit Board  
Table B. Parts List (Figure 7)  
Item  
Qty  
Description  
Part Number  
1
2
1
2
2
1
1
2
1
1
Bracket/Heater Sink  
Heater, 230 VAC  
57004020COMP  
HTR40220  
Heater, 120 VAC  
HTR50120  
3
4
5
6
7
Connector Plug  
CON1-480424-0  
EH470010019  
EH47004029COMP  
PCB9000276ASSY  
EH450010256  
Power Supply Barrier Cover  
Power Supply Barrier  
Circuit Board  
Circuit Board Insulator  
A
B
2
4
2
4
2
2
2
2
Spacer, .375" Length  
SPA8422  
Internal Tooth Lock Washer, #4  
Internal Tooth Lock Washer, #4  
Screw 4-40 x 1/4", Pan Head, Phillips  
Screw 4-40 x 1/4", Pan Head, Phillips  
Grounding Clip  
ZH4LWSIS  
ZH4LWSIS  
C
ZH4-40X.250SPP  
ZH4-40X.250SPP  
570010004  
D
E
F
Screw, 6-32 x 1/4", Pan Head, Phillips  
Internal Star Washer, #6  
ZH6-32X.250SPP  
ZH6LWSIS  
Pelco Manual C397M (4/98)  
17  
 
Figure 8. Wiring Diagram for Enclosure Circuit Board  
18  
Pelco Manual C397M (4/98)  
 
Figure 9. Component Locations for Enclosure Circuit Board  
Figure 10. Layout of Traces on Enclosure Circuit Board  
Pelco Manual C397M (4/98)  
19  
 
8.0 SPECIFICATIONS  
SYSTEM  
Input Voltage:  
120 or 230 VAC, 50/60 Hz  
Power Requirements:  
PT7729RX,  
PT7729WX  
0.35 A (42 vA)  
PT7729RX-1,  
PT7723RX-1,  
PT7729RX-1/PP,  
PT7729RX-1/SL,  
PT7729WX-1,  
PT7723WX-1  
1.7 A (204 vA)  
1.9 A (437 vA)  
PT7729RX-3,  
PT7729RX-3/PP,  
PT7729WX-3  
Power/Control Cables  
All Models:  
Power - 3-wire grounded, 18 AWG, 6 ft (1.83 m)  
Video - RG59, 6 ft (1.83 m)  
PT7729WX,  
PT7729WX-1,  
PT7723WX-1,  
PT7729WX-3  
Wiretron Control - 2-conductor, 18 AWG, 6 ft (1.83 m)  
NEMA Rating:  
Environment:  
Dimensions:  
3R  
Indoor/outdoor -10° to 120° F (-23° to 49° C)  
See Figure 11  
Unit Weight  
PT7723RX-1,  
PT7723WX-1  
48 lbs (21.77 kg)  
49 lbs (22.23 kg)  
PT7729RX,  
PT7729WX  
PT7729RX-1,  
PT7729RX-1/PP,  
PT7729RX-3,  
PT7729RX-3/PP,  
PT7729RX-1/SL,  
PT7729WX-1,  
PT7729WX-3  
53 lbs (24.04 kg)  
20  
Pelco Manual C397M (4/98)  
 
PAN/TILT  
Construction  
Body:  
Aluminum plate  
Side Covers:  
Vacuum-formed ABS plastic, UV protected  
Pan:  
0-355° movement in horizontal plane, except PT7729RX-1/SL,  
which has 360° pan rotation  
Pan Speed:  
Tilt:  
9°/sec ±1° (no load condition)  
+15° movement in vertical plane from horizon  
-90° movement in vertical plane from horizon  
Tilt Speed:  
3°/sec ±5° (no load condition)  
Torque  
Pan:  
Tilt:  
10 ft lbs with specified voltage  
20 ft lbs with specified voltage  
Gearing:  
Adjustable worm-gear final drive to prevent drift and minimize  
backlash  
Bearings:  
Heavy-duty ball bearings on all rotating surfaces  
Instantaneous reversing  
Motors:  
Limit Switches:  
Pan and tilt - 5 A each  
RECEIVER/DRIVER  
Coaxitron® Receiver/Driver  
Fuses:  
One 1 A, 3 AG type  
Two 2/10 A, 3 AG type  
Control Method:  
15-pulse train (pulse width modulated) superimposed on the  
video signal during the vertical interval by the control transmit-  
ter. Pulse train occupies one (1) TV line period.  
Pulse Amplitude: Approximately 1 V p-p added to video signal; 333 KHz nominal  
Input Video:  
1 V p-p nominal; 2 V p-p maximum at less than 75% APL; 1.5  
V p-p maximum at 90% APL  
System Bandwidth: Less than 2 dB down at 10 MHz (exclusive of cable)  
Maximum Operating  
Distance:  
750 ft (229 m) on RG59  
1000 ft (305 m) on RG6  
1500 ft (457 m) on RG1  
(cables above are 75-ohm coax)  
Pelco Manual C397M (4/98)  
21  
 
Wiretron Receiver/Driver  
Fuses:  
One 1 A, 3 AG type  
Two 2/10 A, 3 AG type  
Control Method:  
15 pulse train (pulse width modulated)  
Pulse Amplitude: 35 mA current loop  
Cable  
Requirements:  
Twisted pair, unshielded  
Operating Distance: 22 AWG - 5 miles (8 km)  
20 AWG - 10 miles (16 km)  
ENCLOSURE  
Construction:  
Finish:  
Aluminum  
Gray polyester powder coat  
Glass, 0.25-inch (0.64 cm) thick  
Window:  
Window Viewing  
Area:  
3.8" H x 4.8" W (9.65 x 12.19 cm)  
Camera Mounting: Removable camera than can be inverted to accommodate  
various heights of cameras and lenses  
Maximum  
Camera/Lens Size:  
EH5723  
EH5723-1,-2,-3 15.5" L x 6.25" W x 5.5" H (39.37 x 15.88 x 13.97 cm)  
EH5729 28" L x 7.5" W x 5.5" H (71.12 x 19.05 x 13.97 cm)  
EH5729-1,-2,-3 21.5" L x 6.25 W x 5.5" H (54.61 x 15.88 x 13.97 cm)  
22" L x 7.5" W x 5.5" H (55.88 x 19.05 x 13.97 cm)  
Electrical  
Connections:  
One each of the following:  
3-connector terminal block for power input  
6-pin lens connector  
9-connector terminal block for lens wiring  
10-connector terminal block for camera/lens wiring  
3-pin socket for camera power input  
2-pin socket for blower  
2-pin socket for defroster  
4-pin socket for heaters  
4-pin socket for wiper  
2-pin socket for wiper control  
BNC for video  
Accessory  
Input Power:  
Heater (120 VAC models) 90 watts  
Heater (230 VAC models) 70 watts  
Defroster (all models)  
Blower (all models)  
Wiper (all models)  
30 watts  
15 watts  
15 watts  
(Design and product specifications subject to change without notice.)  
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union  
regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.  
22  
Pelco Manual C397M (4/98)  
 
MODEL  
PT7729RX  
“A”  
“B”  
32.50 (82.55)  
29.00 (73.66)  
PT7729RX-1  
PT7729RX-1/SL  
PT7729RX-1/PP  
PT7729RX-3  
PT7729RX-3/PP  
PT7729WX  
PT7729WX-1  
PT7729WX-3  
PT7723RX-1  
26.50 (67.31)  
23.00 (58.42)  
PT7723RX-1/PP  
PT7723RX-3  
PT7723RX-3/PP  
PT7723WX-1  
Figure 11. Dimension Drawing  
Pelco Manual C397M (4/98)  
23  
 
9.0 WARRANTY AND RETURN INFORMATION  
WARRANTY  
Pelco will repair or replace, without charge, any merchandise proved defective in material or  
workmanship for a period of one year after the date of shipment.  
Exceptions to this warranty are as noted below:  
Five years on FT/FR8000 Series fiber optic products.  
Three years on Genex® Series products (multiplexers, server, and keyboard).  
Three years on Camclosure® and fixed camera models, except the CC3701H-2, CC3701H-2X,  
CC3751H-2,CC3651H-2X,MC3651H-2,andMC3651H-2Xcameramodels,whichhaveafive-  
year warranty.  
Two years on standard motorized or fixed focal length lenses.  
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed  
dome products.  
Two years on Spectra®, Esprit®, ExSite, and PS20 scanners, including when used in  
continuous motion applications.  
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).  
Eighteen months on DX Series digital video recorders, NVR300 Series network video  
recorders, and EnduraSeries distributed network-based video products.  
One year (except video heads) on video cassette recorders (VCRs). Video heads will be  
covered for a period of six months.  
Sixmonthsonallpanandtilts,scannersorpresetlensesusedincontinuousmotionapplications  
(that is, preset scan, tour and auto scan modes).  
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment.  
AllgoodsrequiringwarrantyrepairshallbesentfreightprepaidtoPelco,Clovis,California.Repairs  
made necessary by reason of misuse, alteration, normal wear, or accident are not covered under  
this warranty.  
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the  
specific use or application made of the Products. Pelco’s liability for any claim, whether based on  
breach of contract, negligence, infringement of any rights of any party or product liability, relating  
totheProductsshallnotexceedthepricepaidbytheDealertoPelcoforsuchProducts. Innoevent  
will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss  
of profit and claims of third parties) however caused, whether by the negligence of Pelco or  
otherwise.  
The above warranty provides the Dealer with specific legal rights. The Dealer may also have  
additional rights, which are subject to variation from state to state.  
Ifawarrantyrepairisrequired, theDealermustcontactPelcoat(800) 289-9100or(559)292-1981  
to obtain a Repair Authorization number (RA), and provide the following information:  
1. Model and serial number  
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number  
3. Details of the defect or problem  
If there is a dispute regarding the warranty of a product which does not fall under the warranty  
conditions stated above, please include a written explanation with the product when returned.  
Methodofreturnshipmentshallbethesameorequaltothemethodbywhichtheitemwasreceived  
by Pelco.  
RETURNS  
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800)  
289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit,  
and RA number if returned for repair).  
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.  
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number  
and freight should be prepaid. Ship to the appropriate address below.  
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:  
Service Department  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699  
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed  
to return goods to the USA, you may do one of the following:  
If the goods are to be sent by a COURIER SERVICE, send the goods to:  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699 USA  
Pelco, the Pelco logo, Camclosure, Esprit,  
Genex, Legacy, and Spectra are registered  
trademarks of Pelco.  
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:  
Pelco c/o Expeditors  
473 Eccles Avenue  
South San Francisco, CA 94080 USA  
Phone: 650-737-1700  
Fax: 650-737-0933  
Endura and ExSite are trademarks of Pelco.  
© Copyright 1998, Pelco. All rights reserved.  
24  
Pelco Manual C397M (4/98)  
 

Perreaux Stereo Amplifier SA33 User Manual
Philips Computer Drive SA5MXX User Manual
Philips Headphones SBCH P170 User Manual
Philips Headphones SWS4400 27 User Manual
Philips Iron GC148 User Manual
Philips Washer 191EW9 User Manual
Pinnacle Speakers Network Router Lightning 1000 User Manual
Pioneer Stereo System DRM 1004V40 User Manual
ProForm Home Gym 831288230 User Manual
ProForm Home Gym PFEX3849BX1 User Manual