Pelco Security Camera C3453M B User Manual

I N S T A L L A T I O N  
EH1512  
Series Enclosures  
EH1512 Enclosure with EM1512 Mount  
C3453M-B (4/09)  
 
Important Safety Instructions  
1. Read these instructions.  
2. Keep these instructions.  
3. Heed all warnings.  
4. Follow all instructions.  
5. Do not use this apparatus near water.  
6. Clean only with dry cloth.  
7. Do not block any ventilation openings. Install in accordance with the manufacturers instructions.  
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.  
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one blade wider than the  
other. A grounding plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the  
provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.  
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the points where they exit from  
the apparatus.  
11. Only use attachments/accessories specified by the manufacturer.  
12. Only use with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use  
caution when moving the cart/apparatus combination to avoid injury from tip-over.  
13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-  
supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or  
moisture, does not operate normally, or has been dropped.  
14. Unplug the apparatus during lightning storms or when unused for long periods of time.  
15. Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases shall be placed on the apparatus.  
16. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.  
17. Installation should be done only by qualified personnel and conform to all local codes.  
18. Unless this unit is specifically marked as NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not  
be installed where exposed to rain and moisture.  
19. Only use installation methods and materials capable of supporting four times the maximum specified load.  
20. Only use replacement parts recommended by Pelco.  
21. Do not use attachments, such as mounts, that are not recommended by Pelco. They may be hazardous.  
22. A CCC-approved power cord must be used to power this equipment when used in China.  
The product and/or manual may bear the following marks:  
CAUTION:  
This symbol indicates that dangerous voltage constituting a risk of electric shock is  
present within this unit.  
RISK OF ELECTRIC SHOCK.  
DO NOT OPEN.  
This symbol indicates that there are important operating and maintenance instructions in  
the literature accompanying this unit  
C3453M-B (4/09)  
3
 
 
Description  
The EH1512 Series indoor/outdoor enclosures are designed for use with small- to medium-sized analog and IP cameras. They will accommodate  
both fixed and variable focal length lenses (with or without auto-iris operation). They can be wall mounted using either Pelcos EM1512  
(feedthrough wall mount) or any light to medium duty mount.  
The tethered, removable enclosure lid provides easy access during installation and when camera and lens adjustments are necessary. Power and  
video cabling is brought into the enclosure through two adjustable glands (PG9 and PG11) on the bottom of the enclosure, allowing for easy  
installation.  
Field-installed options include a heater/blower with a 24 VAC camera power supply and sun shroud. The enclosures can also be ordered from the  
factory with a 24 VAC, 120 VAC, or 230 VAC heater/blower with a 24 VAC camera power supply. If your enclosure has a thermostatically  
controlled heater, the thermostat is set to activate at 50°F (10°C) and turn off at 80°F (27°C). The blower operates continuously.  
NOTE: A metric Allen wrench (5 mm) and a Phillips screwdriver are required for installation but are not included. A flat head screwdriver might  
also be needed for all models except the EH1512 and EH1512MT. The Allen wrench is needed to secure the enclosure to all mounts. It is also  
needed to open and close the enclosure and to secure the pan/tilt (swivel head) on the EM1512 mount.  
MODELS  
EH1512  
Enclosure, indoor/outdoor.  
EH1512MT  
EH1512-1  
EH1512-2  
EH1512-3  
EH1512-1MT  
Same as EH1512 with an EM1512 feedthrough wall mount.  
Same as EH1512 with a 120 VAC heater/blower with 24 VAC camera power (includes the 4-inch wire tie).  
Same as EH1512 with a 24 VAC heater/blower with 24 VAC camera power.  
Same as EH1512 with a 230 VAC heater/blower with 24 VAC camera power (includes the 4-inch wire tie).  
Same as EH1512 with a 120 VAC heater/blower with 24 VAC camera power and an EM1512 feedthrough wall mount  
(includes the 4-inch wire tie).  
EH1512-2MT  
EH1512-3MT  
Same as EH1512 with a 24 VAC heater/blower with 24 VAC camera power and an EM1512 feedthrough wall mount.  
Same as EH1512 with a 230 VAC heater/blower with 24 VAC camera power and an EM1512 feedthrough wall mount  
(includes the 4-inch wire tie).  
EH1512-1MTS  
EH1512-2MTS  
EH1512-3MTS  
Same as EH1512 with a 120 VAC heater/blower with 24 VAC camera power, an EM1512 feedthrough wall mount (includes  
the 4-inch wire tie), and an SS1512 sun shroud.  
Same as EH1512 with a 24 VAC heater/blower with 24 VAC camera power, an EM1512 feedthrough wall mount, and an  
SS1512 sun shroud.  
Same as EH1512 with a 230 VAC heater/blower with 24 VAC camera power, an EM1512 feedthrough wall mount (includes  
the 4-inch wire tie), and an SS1512 sun shroud.  
4
C3453M-B (4/09)  
 
   
PACKAGE CONTENTS  
NOTE: A metric Allen wrench (5 mm) is required for installation but is not included. A Phillips screwdriver, flat head screwdriver, or 1/4-inch nut  
driver is needed for the EH1512-1 and EH1512-3 only. The Allen wrench is needed to open and close the enclosure and to secure the enclosure to  
all mounts. It is also needed to secure the pan/tilt (swivel head) on the EM1512 mount.  
The following items are supplied:  
Qty Description  
1
1
1
2
2
1
1
1
1
1
1
EH1512 Series enclosure  
Screw, 1/4-20 x 3/8-inch, Phillips  
Washer, 1/4-inch split lock  
Screws, M6 x 1.0 P x 12 mm, hex socket cap  
Washers, 6 mm split lock  
Gland and nut, PG9 cable  
Gland and nut, PG11 cable  
Wire tie, 4-inch (EH1512-1 and EH1512-3 only)  
Installation manual  
EM1512 mount (optional)  
SS1512 sun shroud (optional)  
SHIPPING BOX  
EH1512 ENCLOSURE  
1 EA.  
WIRE  
TIE  
1 EA.  
GLANDS AND NUTS  
2 EA.  
HEX SOCKET  
CAP SCREW  
2 EA.  
6MM  
SPLIT  
WASHERS  
2 EA.  
PHILLIPS  
SCREW  
1 EA.  
1/4-INCH  
SPLIT  
WASHER  
1 EA.  
MOUNT  
1 EA.  
(OPTIONAL)  
SUN SHROUD  
1 EA.  
(OPTIONAL)  
Figure 1. Package Contents  
C3453M-B (4/09)  
5
 
   
Installation  
INSTALLING THE CAMERA AND MOUNT  
To install the enclosure, camera, and lens:  
1. Use a 5-mm Allen wrench (not supplied) to loosen the three screws on the enclosure base.  
2. Lift up and remove the lid (refer to Figure 2). Hang the lid from the front of the enclosure base by the lanyards.  
NOTE: The gasket can come loose when the lid is removed. Be sure to properly reseat the gasket, if necessary.  
Figure 2. Removing the Lid  
6
C3453M-B (4/09)  
 
     
3. Remove the camera sled from the enclosure rail (refer to Figure 3).  
a. Squeeze the two plastic tabs (located near the front window) that hold the camera sled in place.  
b. Pull up and slide the sled forward.  
c. Remove the sled.  
Figure 3. Removing the Sled  
4. Remove the parts bag. This includes the screws, split washers, glands, and nuts.  
5. Remove the glands and nuts from the parts bag and perform one of the following options:  
Wiring the enclosure with the cable not in conduit (for example, if using the EM1512 mount): Install and tighten the glands and  
nuts in the bottom of the enclosure. Refer to Table A on page 10 for allowable cable diameter for the glands.  
NOTE: The PG11 gland might not accommodate RX11 coaxial cable because the coaxial diameter might be larger than the gland,  
0.395 inches (0.10 cm).  
Glands can be mounted either inside or outside of the enclosure. When using the EM1512 feedthrough mount, Pelco recommends  
mounting the glands inside the enclosure with the nuts on the outside.  
Wiring the enclosure with conduit: Use a step drill to drill the larger hole to 0.875 inches (2.22 cm) for 1/2-inch conduit.  
6. Steps 7, 8, and 9 contain instructions for installing the EM1512 mount. If you are using a mount other than the EM1512, refer to the specific  
mount manual for installation instructions, and then go to step 10.  
C3453M-B (4/09)  
7
 
 
7. If you are using the EM1512 mount, attach the mount to the wall as follows:  
a. Using the mount as a template, mark and drill holes in the mounting surface.  
b. Pull the video and power cables from the wall through the mount. If wiring with conduit, use a step drill to drill a 0.875 inches (2.22 cm)  
hole in one of the three knockout locations for 1/2-inch conduit. (Knockouts are indicated on the side and bottom of the mount arm.)  
Refer to Table B on page 10 to determine the size of the power wire needed. Refer to Table D on page 11 to determine the type of video  
coaxial cable needed.  
c. Fasten the mount to the wall using a minimum of two flat washers (not supplied) and two 1/4-20 bolts (not supplied).  
WARNINGS:  
• If you install the mount outdoors, rainwater could leak through the mounting bolt holes and damage the wall. To prevent  
water damage, seal the bolt holes with an appropriate sealant. Apply the sealant around the bolt holes between the mount  
and the mounting surface.  
• Use fasteners of a suitable size, and make certain the mounting surface can support the combined weight of the mount and  
camera/enclosure.  
d. Pull the cables through the glands in the enclosure. If the glands are mounted outside the enclosure, tighten the glands around the  
cables. (If the glands are mounted inside the enclosure, do not tighten the glands around the cables until after you perform step 8.)  
8. Attach the enclosure using the threaded mounting holes in the bottom of the enclosure. Use the M6 bolts and 6 mm split washer (supplied  
in the parts bag). Tighten the bolts to attach the enclosure body to the mount surface. Tighten the glands around the cables.  
9. Adjust the enclosure position by loosening the M6 bolt at the bottom of the mount. Position the mount as desired, and then tighten the M6 bolt.  
10. If you are not using the EM1512, pull the video and power cables through the glands or conduit on the bottom of the enclosure. Refer to Table B  
on page 10 to determine the size of power wire needed. Refer to Table D on page 11 to determine the type of video coaxial cable needed.  
NOTE: Be sure to route all coaxial cable and wiring along the sides of the enclosure to avoid heating problems. Maintain separation between  
120/230 VAC, 24 VAC, and video wiring.  
11. Adjust the glands for a tight fit around the cables. If you are wiring the enclosure with conduit, install the fittings to connect the conduit to  
the enclosure.  
12. Attach the camera to the sled with the Phillips screw and split washer (supplied in the parts bag), refer to Figure 4. Align the front of the  
lens with the front edge of the sled. Tighten the screw, and then reinsert the sled.  
Figure 4. Attaching the Camera to the Sled  
13. Refer to Figure 5 on page 9 for wiring power to the enclosure and the camera.  
14. Attach the video cables to the camera.  
15. If required, connect the ground to the boss and screw on the bottom of the enclosure, which is located in front of the PC board. For  
EH1512-1 and EH1512-3, pass the supplied zip tie through the hole in the PCB cover to secure the input power wires to the PCB cover.  
16. Adjust the camera focal length and focus, if necessary.  
17. Position the enclosure lid, close it, and then tighten the screws using a 5-mm Allen wrench (not supplied). When tightening the screws,  
ensure the gasket is properly seated.  
8
C3453M-B (4/09)  
 
 
120 VAC MODEL WIRING  
24 VAC CAMERA OUTPUT  
24 VAC CAMERA OUTPUT  
LOW  
HIGH  
HI LOW  
24 VAC  
AC IN AC OUT  
HI NT HI NT  
INPUT, AC HIGH  
INPUT, AC LOW (NEUTRAL)  
ZIP TIE HERE  
120 VAC CAMERA OUTPUT, LOW (NEUTRAL)  
0 - GROUND BOSS  
120 VAC OUTPUT, HIGH  
24 VAC MODEL WIRING  
INPUT, AC LOW (NEUTRAL)  
INPUT, AC HIGH  
LOW HI  
AC AC  
CAMERA  
CAMERA OUTPUT, AC LOW (NEUTRAL)  
CAMERA OUTPUT, AC HIGH  
230 VAC MODEL WIRING  
24 VAC CAMERA OUTPUT  
24 VAC CAMERA OUTPUT  
LOW  
HIGH  
HI LOW  
24 VAC  
AC IN AC OUT  
HI NT HI NT  
INPUT, AC HIGH  
INPUT, AC LOW (NEUTRAL)  
ZIP TIE HERE  
230 VAC CAMERA OUTPUT, LOW (NEUTRAL)  
0 - GROUND BOSS  
230 VAC OUTPUT, HIGH  
Figure 5. EH1512 Wiring Diagram  
C3453M-B (4/09)  
9
 
 
INSTALLING THE SUN SHROUD  
The optional sun shroud fits over the top of the EH1512 enclosure. Perform the following steps to install the sun shroud.  
1. Position the front of the sun shroud above the front of the enclosure.  
2. Press the sun shroud down and against the enclosure until the sun shroud snaps into place.  
Table A. Allowable Cable Diameter  
Gland  
PG9  
Cable Diameter  
0.181-inch to 0.312-inch  
0.230-inch to 0.395-inch  
PG11  
NOTE: Conduit must be used if the cable diameter  
is greater than 0.395 inches (1.00 cm). RG11 coaxial  
might be greater than 0.395 inches.  
Table B describes the minimum recommended cable sizes needed for use with the heater and blower combinations in the EH1512 enclosure.  
WARNING: When using a single power source for both camera and accessories, consider the camera power consumption when  
determining the wire gauge. Table B does not include camera power.  
Table B. Enclosure Accessory Wiring Distances  
Maximum Power  
Consumption  
Model Number  
Input Voltage  
Cable Size  
Cable Distance  
20 AWG  
18 AWG  
16 AWG  
14 AWG  
2,782 ft (848 m)  
4,424 ft (1,348 m)  
7,035 ft (2,144 m)  
11,184 ft (3,409 m)  
EH1512-1  
120 VAC  
22 W  
20 AWG  
18 AWG  
16 AWG  
14 AWG  
142 ft (43 m)  
225 ft (69 m)  
358 ft (109 m)  
569 ft (173 m)  
EH1512-2  
EH1512-3  
24 VAC  
230 VAC  
120 VAC  
24 VAC  
22 W  
22 W  
22 W  
22 W  
22 W  
20 AWG  
18 AWG  
16 AWG  
14 AWG  
6,473 ft (1,973 m)  
10,291 ft (2,137 m)  
16,365 ft (4,988 m)  
26,019 ft (7,931 m)  
20 AWG  
18 AWG  
16 AWG  
14 AWG  
2,782 ft (848 m)  
4,424 ft (1,348 m)  
7,035 ft (2,144 m)  
11,184 ft (3,409 m)  
EH1512-1MT,  
EH1512-1MTS  
20 AWG  
18 AWG  
16 AWG  
14 AWG  
142 ft (43 m)  
225 ft (69 m)  
358 ft (109 m)  
569 ft (173 m)  
EH1512-2MT,  
EH1512-2MTS  
20 AWG  
18 AWG  
16 AWG  
14 AWG  
6,473 ft (1,973 m)  
10,291 ft (2,137 m)  
16,365 ft (4,988 m)  
26,019 ft (7,931 m)  
EH1512-3MT,  
EH1512-3MTS  
230 VAC  
10  
C3453M-B (4/09)  
 
     
Table C. 24 VAC Wiring Distances  
Wire Gauge  
Total VA  
20 AWG (0.5 mm2) 18 AWG (1.0 mm2) 16 AWG (1.5 mm2) 14 AWG (2.5 mm2)  
10  
20  
30  
40  
50  
283 ft (86 m)  
141 ft (42 m)  
94 ft (28 m)  
70 ft (21 m)  
56 ft (17 m)  
451 ft (137 m)  
225 ft (68 m)  
150 ft (45 m)  
112 ft (34 m)  
90 ft (27 m)  
716 ft (218 m)  
358 ft (109 m)  
238 ft (54 m)  
179 ft (54 m)  
143 ft (43 m)  
1142 ft (348 m)  
571 ft (174 m)  
380 ft (115 m)  
285 ft (86 m)  
228 ft (69 m)  
Table C describes the recommended maximum distances for 24 VAC applications, which are calculated with a 10 percent voltage drop. (Ten  
percent is generally the maximum allowable voltage drop for AC-powered devices.)  
For example, an enclosure that requires 30 VA and is installed 94 feet (28 m) from the transformer would require a minimum wire gauge of  
20 AWG.  
Table D. Video Coaxial Cable Wiring Distance  
Cable Type*  
Maximum Distance  
RG59/U  
RG6/U  
RG11/U  
750 ft (229 m)  
1,000 ft (305 m)  
1,500 ft (457 m)  
*Minimum Cable Requirements:  
75-ohm impedance  
All-copper center conductor  
All-copper braided shield with 95% braid coverage  
Maintenance  
Clean the window regularly to maintain picture clarity. Use a soft cloth and a mild, nonabrasive detergent and water.  
C3453M-B (4/09)  
11  
 
     
Specifications  
MODELS  
Model Number  
EH1512  
EH1512MT  
12 W  
12 W  
12 W  
12 W  
12 W  
12 W  
12 W  
12 W  
12 W  
25 W  
EH1512-1  
EH1512-2  
25 W  
25 W  
EH1512-3  
EH1512-1MT  
EH1512-2MT  
EH1512-3MT  
EH1512-1MTS  
EH1512-2MTS  
EH1512-3MTS  
25 W  
25 W  
25 W  
*Enclosure power consumption does not include camera wattage.  
MECHANICAL  
Camera Mounting  
Single slot for adjustable camera positioning on snap-in camera sled  
Accepts camera and lens combinations(including BNC connector) up to 9.00" L x 2.87" W x 3.00" H  
(22.86 x 7.28 x 7.62 cm)  
Camera and Lens Size  
Viewing Window  
Viewing Area  
Cable Entry  
0.118-inch (3 mm) thick scratch-resistant Lexan®  
2.81" W x 2.47" H (7.14 x 6.27 cm)  
1 x PG9 and 1 x PG11 compression glands on bottom; PG9 0.312-inch (0.8 cm) and PG11 0.395 (1.0 cm)  
maximum cable diameters  
Cable Entry Holes  
Lid Fastening  
1 x 0.750-inch (1.91 cm) diameter and 1 x 0.630-inch (1.6 cm) diameter;  
0.750-inch hole will accept 1/2-inch NPT conduit fitting when enlarged to 0.875-inch;  
0.630-inch hole will accept 1/4-inch NPT conduit fitting  
3 Allen-head screws  
GENERAL  
Construction  
Die-cast aluminum  
Finish  
Environment‡  
Alodine with gray polyester powder coat  
Indoor/outdoor ambient temperature -10° to 120° F (-23° to 49° C)  
Unit Length  
Base  
Overall  
13.38 inches (33.99 cm)  
14.39 inches (36.55 cm)  
*Maximum recommended camera power consumption is 6.7 watts.  
Assumes the lens is fully extended.  
Check the environmental specification of your specific camera/lens.  
12  
C3453M-B (4/09)  
 
 
Unit Weight  
EH1512  
EH1512MT  
EH1512-1  
EH1512-2  
EH1512-3  
EH1512-1MT  
EH1512-2MT  
EH1512-3MT  
EH1512-1MTS  
EH1512-2MTS  
EH1512-3MTS  
2.50 lb (1.13 kg)  
3.13 lb (1.42 kg)  
3.25 lb (1.47 kg)  
2.56 lb (1.16 kg)  
3.25 lb (1.47 kg)  
3.88 lb (1.76 kg)  
3.19 lb (1.45 kg)  
3.88 lb (1.76 kg)  
4.76 lb (2.16 kg)  
4.07 lb (1.85 kg)  
4.76 lb (2.16 kg)  
Shipping Weight  
EH1512  
EH1512MT  
EH1512-1  
EH1512-2  
4 lb (1.81 kg)  
5 lb (2.27 kg)  
5 lb (2.27 kg)  
4 lb (1.81 kg)  
5 lb (2.27 kg)  
5 lb (2.27 kg)  
4 lb (1.81 kg)  
5 lb (2.27 kg)  
6 lb (2.72 kg)  
5 lb (2.27 kg)  
6 lb (2.72 kg)  
EH1512-3  
EH1512-1MT  
EH1512-2MT  
EH1512-3MT  
EH1512-1MTS  
EH1512-2MTS  
EH1512-3MTS  
OPTIONAL ACCESSORIES  
Blower Kit  
EH1512-1BKIT  
EH1512-2BKIT  
EH1512-3BKIT  
Continuous duty, 120 VAC, 1 W, 1.45 cfm  
Continuous duty, 24 VAC, 1 W, 1.45 cfm  
Continuous duty, 230 VAC, 1 W, 1.45 cfm  
Heater/Blower Kit  
EH1512-1HBKIT  
EH1512-2HBKIT  
EH1512-3HBKIT  
120 VAC, 11 W  
24 VAC, 11 W  
230 VAC, 11 W  
NOTE: Heaters are thermostatically controlled to activate at 50°F (10°C) and turn off at 80°F (27°C). The blower operates continuously.  
Sun Shroud  
Marine Kit  
Security Kit  
SS1512  
EH-MKIT (requires EM1512 or EM1450 wall mount)  
EH-SKIT for EH1512 (3 screws and 1 bit)  
RECOMMENDED MOUNTS  
Wall  
EM1512  
EM1450  
Wall mount with feedthrough for EH1512 (tilt angle of +20° to -70°; sustains wind velocity up to 90 mph)  
Light duty wall mount; maximum load 20 lb (9.07 kg)  
EM2400  
EM1900U, EM22  
Medium duty wall mount; maximum load 40 lb (18.14 kg) with feedthrough (tilt angle of 90°)  
Medium duty wall mount; maximum load 40 lb (18.14 kg)  
Pedestal  
EM1009U, EM1015U, MM22  
Medium duty pedestal mount; maximum load 40 lb (18.14 kg)  
Pipe/Pole  
EM1109, EM2000, EM2200  
Medium duty mounts for pipe/pole applications; maximum load 40 lb (18.14 kg); fits poles with  
3-inch (7.62 cm) to 8-inch (20.32 cm) diameter  
Ceiling  
EM3000  
Light duty ceiling J-mount; maximum load 20 lb (9.07 kg); 360° pan rotation; 75° tilt angle  
C3453M-B (4/09)  
13  
 
RECOMMENDED CAMERAS AND LENSES  
Cameras  
C10CH-6, C10CH-6X, C10CH-7X, C10DN-6, C10DN-6X, C10DN-7X, CCC1390H-6, CCC1390H-6X,  
IP3701H-2, IP3701H-2X, IXS0C, IXS0DN, IX10C, IX10DN, IXE20C, IXE20DN, IX30C, IX30DN  
Lenses  
13VD2.8-12, 13VD3-8, 13VD5-40, 13VD5-50, 13VDIR2.8-11, 13VDIR3-8.5, 13VDIR7.5-50  
NOTE: These lenses are for use with all cameras except Pelco IP cameras with Sarix™ technology. Refer  
to the specific camera specification sheet for information on recommended lenses.  
(Design and product specifications subject to change without notice.)  
3.80  
(9.65)  
16.01 (40.67)  
3.27 (8.31)  
2.64 (6.71)  
4.94  
(12.55)  
14.00 (35.56)  
SS1512 Sun Shroud  
4.47  
(11.35)  
14.39 (36.55)  
3.78 (9.60)  
13.38 (33.99)  
EH1512 Camera Enclosure  
2.61  
(6.63)  
2.56  
(6.50)  
1.50  
(3.81)  
6.00  
(15.24)  
0.75  
(1.91)  
4.02  
(10.21)  
3.60  
(9.14)  
2.84  
(7.21)  
5.74  
(14.58)  
EM1512 Wall Mount  
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES.  
14  
C3453M-B (4/09)  
 
PRODUCT WARRANTY AND RETURN INFORMATION  
WARRANTY  
Pelco will repair or replace, without charge, any merchandise proved defective in  
material or workmanship for a period of one year after the date of shipment.  
Pelco will warrant all replacement parts and repairs for 90 days from the date of  
Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid  
to a Pelco designated location. Repairs made necessary by reason of misuse,  
alteration, normal wear, or accident are not covered under this warranty.  
Exceptions to this warranty are as noted below:  
• Five years:  
Pelco assumes no risk and shall be subject to no liability for damages or loss  
resulting from the specific use or application made of the Products. Pelcos liability  
for any claim, whether based on breach of contract, negligence, infringement of  
any rights of any party or product liability, relating to the Products shall not exceed  
the price paid by the Dealer to Pelco for such Products. In no event will Pelco be  
liable for any special, incidental, or consequential damages (including loss of use,  
loss of profit, and claims of third parties) however caused, whether by the  
negligence of Pelco or otherwise.  
Fiber optic products  
TW3000 Series unshielded twisted pair (UTP) transmission products  
CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and  
MC3651H-2X camera models  
• Three years:  
Pelco-branded fixed camera models (CCC1390H Series, C10DN Series,  
C10CH Series, IP3701H Series, and IX Series)  
EH1500 Series enclosures  
Spectra® IV products (including Spectra IV IP)  
Camclosure® Series (IS, ICS, IP) integrated camera systems  
The above warranty provides the Dealer with specific legal rights. The Dealer may  
also have additional rights, which are subject to variation from state to state.  
DX Series digital video recorders, DVR5100 Series digital video recorders,  
Digital Sentry® Series hardware products, DVX Series digital video  
recorders, and NVR300 Series network video recorders  
Endura® Series distributed network-based video products  
Genex® Series products (multiplexers, server, and keyboard)  
PMCL200/300/400 Series LCD monitors  
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or  
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the  
following information:  
1. Model and serial number  
2. Date of shipment, P.O. number, sales order number, or Pelco invoice number  
3. Details of the defect or problem  
• Two years:  
If there is a dispute regarding the warranty of a product that does not fall under  
the warranty conditions stated above, please include a written explanation with  
the product when returned.  
Standard varifocal, fixed focal, and motorized zoom lenses  
DF5/DF8 Series fixed dome products  
Legacy® Series integrated positioning systems  
Spectra III, Spectra Mini, Spectra Mini IP, Esprit®, ExSite®, and PS20  
scanners, including when used in continuous motion applications.  
Method of return shipment shall be the same or equal to the method by which the  
item was received by Pelco.  
Esprit Ti and TI2500 Series thermal imaging products  
Esprit and WW5700 Series window wiper (excluding wiper blades).  
CM6700/CM6800/CM9700 Series matrix  
RETURNS  
To expedite parts returned for repair or credit, please call Pelco at (800) 289-9100  
or (559) 292-1981 to obtain an authorization number (CA number if returned for  
credit, and RA number if returned for repair) and designated return location.  
Digital Light Processing (DLP®) displays (except lamp and color wheel). The  
lamp and color wheel will be covered for a period of 90 days. The air filter is  
not covered under warranty.  
Intelli-M® eIDC controllers  
All merchandise returned for credit may be subject to a 20 percent restocking and  
refurbishing charge.  
• One year:  
Video cassette recorders (VCRs), except video heads. Video heads will be  
covered for a period of six months.  
• Six months:  
All pan and tilts, scanners, or preset lenses used in continuous motion  
applications (preset scan, tour, and auto scan modes).  
Goods returned for repair or credit should be clearly identified with the assigned  
CA or RA number and freight should be prepaid.  
12-23-08  
The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC.  
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union  
regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.  
REVISION HISTORY  
Manual #  
C3453M  
C3453M-A  
Date  
12/08  
3/09  
Comments  
Original version.  
Updated the manual to describe the change in the lanyard position and the revised maximum power consumption and heater/blower kit power specifications.  
A Phillips screwdriver is now required; a flat head screwdriver is required for certain models. A screw was added to the end of the enclosure. Revised figures 1  
and 2, the enclosure specification drawing, the model table in the specification section, and added Sarix cameras to the recommended camera list.  
Added security kit EH-SKIT to the list of optional accessories.  
C3453M-B  
4/09  
Pelco, the Pelco logo, Camclosure, Digital Sentry, Endura, Esprit, ExSite, Genex, Intelli-M, Legacy, and Spectra are registered trademarks of Pelco, Inc.  
Spectra III is a trademark of Pelco, Inc.  
© Copyright 2009, Pelco, Inc. All rights reserved.  
DLP is a registered trademark of Texas Instruments Incorporated.  
All product names and services identified throughout this document are trademarks or registered trademarks of their respective companies.  
The absence of a trademark or registered trademark from this document does not constitute a waiver of intellectual property rights.  
 
Pelco, Inc. Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA  
USA & Canada Tel (800) 289-9100 Fax (800) 289-9150  
International Tel +1 (559) 292-1981 Fax +1 (559) 348-1120  
 

Pelco Switch VS5108 User Manual
Philips Battery Charger SCB3021 User Manual
Philips Car Satellite TV System 42PFL7603D User Manual
Philips Cassette Player Stereo Radio Cassette Recorder User Manual
Philips CRT Television TS2546C1 User Manual
Philips Headphones SHC8585 00 User Manual
Philips Indoor Furnishings SB6G17 User Manual
Porter Cable Nail Gun PN650 User Manual
Powermatic Saw PWBS 14 User Manual
ProMounts TV Mount UTPRO410 User Manual